Evidence map›Paper›PMID 30306219›Full record

ArticleInternational orthopaedics2019

Screw tip augmentation leads to improved primary stability in the minimally invasive treatment of displaced intra-articular fractures of the calcaneus: a biomechanical study.

Martin Eichinger, Alexander Brunner, Hannes Stofferin, Andreas Bölderl, Michael Blauth, Werner Schmölz

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Martin EichingerDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria. martin.eichinger@tirol-kliniken.at.ORCID 0000-0003-2461-7403
Alexander BrunnerDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
Hannes StofferinDepartment of Anatomy, Histology and Embryology, Division of Clinical and Functional Anatomy, Medical University of Innsbruck, Müllerstrasse 59, 6020, Innsbruck, Austria.
Andreas BölderlDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
Michael BlauthDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
Werner SchmölzDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate if the stability of minimally invasive screw osteosynthesis of displaced intra-articular calcaneal fractures (DIACF) can be effectively increased by an innovative approach to screw tip augmentation.

methodsIn eight-paired human cadaver hindfoot specimens, DIACF of Sanders type IIB were treated with either standard screw osteosynthesis or with bone cement augmentation of the screw tips in the main fragments. The instrumented specimens were subjected to a cyclic loading protocol (9000 cycles, with stepwise increasing loads, 100-1000 N). The interfragment motions were quantified as tuber fragment tilt (TFT) and posterior facet inclination angle (PFIA) using a 3-D motion analysis system. Böhler's angle (BA) was evaluated from X-rays. A load-to-failure test was performed after the cyclic loading protocol.

resultsAll but one specimen of the augmented group withstood more cycles than the respective specimens of the non-augmented group. Mean cycles to failure for the failure criterion of 5° TFT were 7299 ± 1876 vs. 3864 ± 1810, corresponding to loads of 811 N ± 195 vs. 481 N ± 180, (P = 0.043). There were no significant differences observed in the PFIAs. The failure criterion of 5° BA was reached after a mean of 7929 cycles ± 2004 in the augmented group and 4129 cycles ± 2178 in the non-augmented group, corresponding to loads of 893 N ± 200 vs. 513 N ± 218, (P = 0,090). The mean load-to-failure of the four specimens in the augmented group that completed the cyclic loading was 1969 N over a 1742-2483 N range.

conclusionScrew tip augmentation significantly improved the mechanical stability of the calcanei after osteosynthesis in terms of decreased tuber fragment tilts and less changes in Böhler's angle.

Indexed as

Bone ScrewsAgedBiomechanical PhenomenaCadaverCalcaneusFemaleFracture Fixation, InternalHumansIntra-Articular FracturesMaleMiddle AgedMinimally Invasive Surgical ProceduresAugmentationBiomechanicsCalcaneus fractureCementScrew fixation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.