Evidence map›Paper›PMID 30305126›Full record

ArticleJournal of orthopaedic surgery and research2018

Effect of pedicle screw augmentation with a self-curing elastomeric material under cranio-caudal cyclic loading-a cadaveric biomechanical study.

Werner Schmoelz, Alexander Keiler, Marko Konschake, Richard A Lindtner, Alessandro Gasbarrini

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Can cavity-based pedicle screw augmentation decrease screw loosening? A biomechanical in vitro study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Werner SchmoelzDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria. Werner.schmoelz@i-med.ac.at.ORCID http://orcid.org/0000-0003-2962-2594
Alexander KeilerDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria.
Marko KonschakeDepartment of Anatomy, Histology and Embryology, Medical University of Innsbruck, Innsbruck, Austria.
Richard A LindtnerDepartment of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria.
Alessandro GasbarriniInstituto Orthopedic Rizzoli, Bologna, Italy.
Innsbruck Medical University · ATIstituto Ortopedico Rizzoli · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPedicle screws can be augmented with polymethylmethacrylate (PMMA) cement through cannulated and fenestrated pedicle screws to improve screw anchorage. To overcome the drawbacks of PMMA, a modified augmentation technique applying a self-curing elastomeric material into a balloon-created cavity prior to screw insertion was developed and evaluated. The aim of the study was to compare the effect of the established and novel augmentation technique on pedicle screw anchorage in a biomechanical in vitro experiment.

methodsIn ten lumbar vertebral bodies, the right pedicles were instrumented with monoaxial cannulated and fenestrated pedicle screws and augmented in situ with 2 ml PMMA. The left pedicles were instrumented with monoaxial cannulated pedicle screws. Prior to left screw insertion, a balloon cavity was created and filled with 3 ml of self-curing elastomer (silicone). Each screw was subjected to a cranio-caudal cyclic load starting from - 50 to 50 N while the upper load was increased by 5 N every 100 load cycles until loosening or 11,000 cycles (600 N). After cyclic loading, a pullout test of the screws was conducted.

resultsThe mean cycles to screw loosening were 9824 ± 1982 and 7401 ± 1644 for the elastomer and PMMA group, respectively (P = 0.012). The post-cycling pullout test of the loosened screws showed differences in the failure mode and failure load, with predominantly pedicle/vertebrae fractures in the PMMA group (1188.6 N ± 288.1) and screw pullout through the pedicle (671.3 N ± 332.1) in the elastomer group.

conclusionThe modified pedicle screw augmentation technique involving a balloon cavity creation and a self-curing elastomeric silicone resulted in a significantly improved pedicle screw anchorage under cyclic cranio-caudal loading when compared to conventional in situ PMMA augmentation.

Indexed as

Bone CementsPedicle ScrewsAgedAged, 80 and overBiomechanical PhenomenaElastomersFemaleHumansLumbar VertebraeMaleMaterials TestingPolymethyl MethacrylateSacrumSkullWeight-BearingBone CementsElastomersPolymethyl MethacrylateElastoplastyIn situ screw augmentationPedicle screw anchoragePMMAScrew augmentationSilicone

Identifiers

PMID30305126
PMCPMC6180648
OpenAlexW2898067296

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.