Evidence map›Paper›PMID 30302923›Full record

ArticleJournal of biophotonics2019

Super-achromatic optical coherence tomography capsule for ultrahigh-resolution imaging of esophagus.

Kaiyan Li, Wenxuan Liang, Jessica Mavadia-Shukla, Hyeon-Cheol Park, Dawei Li, Wu Yuan, Suiren Wan, Xingde Li

Abstract read
In one paragraph

Article in Journal of biophotonics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Towards OCT-Guided Endoscopic Laser Surgery-A Review.Diagnostics (Basel, Switzerland) · 2023
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. A review of low-cost and portable optical coherence tomography.Progress in biomedical engineering (Bristol, England) · 2021
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kaiyan LiSchool of Biological Science & Medical Engineering, Southeast University, Nanjing, Jiangsu, China.ORCID 0000-0003-2275-5984
Wenxuan LiangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland.
Jessica Mavadia-ShuklaDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland.
Hyeon-Cheol ParkDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland.
Dawei LiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland.
Wu YuanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland.
Suiren WanSchool of Biological Science & Medical Engineering, Southeast University, Nanjing, Jiangsu, China.
Xingde LiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland.

Funding

Micro Coherence Imaging Technology for Assessing Obstructive Lung Disease in vivoR01HL121788 · NHLBI · JOHNS HOPKINS UNIVERSITY · PI BROWN, ROBERT H, LI, XINGDE · 2014 to 2018
$3.7M
Nonlinear Optical Endomicroscopy for Optical Biopsy of Cancer in Internal OrgansR01CA153023 · NCI · JOHNS HOPKINS UNIVERSITY · PI LI, XINGDE · 2011 to 2015
$2.6M
NCI NIH HHS R01 CA153023NHLBI NIH HHS R01 HL121788
6 · The paper itself

Abstract

Endoscopic optical coherence tomography (OCT) is a noninvasive technology allowing for imaging of tissue microanatomies of luminal organs in real time. Conventional endoscopic OCT operates at 1300 nm wavelength region with a suboptimal axial resolution limited to 8-20 μm. In this paper, we present the first ultrahigh-resolution tethered OCT capsule operating at 800 nm and offering about 3- to 4-fold improvement of axial resolution (plus enhanced imaging contrast). The capsule uses diffractive optics to manage chromatic aberration over a full ~200 nm spectral bandwidth centering around 830 nm, enabling to achieve super-achromaticity and an axial resolution of ~2.6 μm in air. The performance of the OCT capsule is demonstrated by volumetric imaging of swine esophagus ex vivo and sheep esophagus in vivo, where fine anatomic structures including the sub-epithelial layers are clearly identified. The ultrahigh resolution and excellent imaging contrast at 800 nm of the tethered capsule suggest the potential of the technology as an enabling tool for surveillance of early esophageal diseases on awake patients without the need for sedation.

Indexed as

Signal-To-Noise RatioAnimalsEsophagusImage Processing, Computer-AssistedLasersSheepTomography, Optical Coherencecapsuleendoscopic optical coherence tomographyesophagussuper-achromaticultrahigh resolution

Identifiers

PMID30302923
PMCPMC6416074

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.