Evidence map›Paper›PMID 30300364›Full record

ArticlePloS one2018

Safety of intrauterine devices in MRI.

Simon Bussmann, Roger Luechinger, Johannes M Froehlich, Constantin von Weymarn, Carolin Reischauer, Dow Mu Koh, Andreas Gutzeit

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.8field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Recent advances in bioelectronics chemistry.Chemical Society reviews · 2020
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Simon BussmannDepartment of Chemistry and Applied Biosciences, ETH Zuerich, Zuerich, Switzerland.ORCID 0000-0002-9338-1919
Roger LuechingerInstitute for Biomedical Engineering, University and ETH Zuerich, Zuerich, Switzerland.
Johannes M FroehlichDepartment of Chemistry and Applied Biosciences, ETH Zuerich, Zuerich, Switzerland.
Constantin von WeymarnDepartment of Radiology, Clinical Research unit of St. Anna Hospital Luzern, Lucerne, Switzerland.
Carolin ReischauerDepartment of Radiology, Clinical Research unit of St. Anna Hospital Luzern, Lucerne, Switzerland.
Dow Mu KohDepartment of Radiology, Royal Marsden Hospital, Sutton, United Kingdom.
Andreas GutzeitDepartment of Chemistry and Applied Biosciences, ETH Zuerich, Zuerich, Switzerland.
Hirslanden Klinik St. Anna · CHInstitute for Biomedical Engineering · CHParacelsus Medical University · ATRoyal Marsden Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe paucity of safety information on intrauterine devices (IUD) for magnetic resonance imaging (MRI) examinations is clinically relevant. The aim of this study is to evaluate the MRI safety of clinically used IUDs composed of copper/gold and stainless steel at 1.5T and 3.0T. MATERIALS AND

methodsWe assessed and compared the displacement force, torque effects, presence of imaging artifacts and heating of IUDs composed of copper/gold (western IUDs) and stainless steel (China) on 1.5 and 3.0T MRI systems.

resultsGold/Copper IUDs can show small deflection angles of 7° ± 7° in the worst-case field gradient of 40T/m (equivalent to magnetic force of 0.5 mN), while the stainless steel IUD experienced significant magnetic force and deflection (Force > 7.5 N; deflection angle 90° ± 1°). Manual rotation and suspension method show no torque effects on gold/copper IUDs but high torque effects were observed by manual rotation on the stainless steel IUD. Heating measurements showed a temperature increase (rescaled to a wbSAR of 4 W/kg) of 1.4°C at 1.5T / 3.4°C at 3.0 T (stainless steel IUD), 3.2°C at 1.5 T / 3.8°C at 3 T (copper/gold IUD), 3.3°C at 1.5 T / 4.8°C at 3 T (copper 1), 3.8°C at 1.5 T / 4.8°C at 3 T (copper 2). The visible imaging artifacts of the copper and gold IUDs at 3 T MRI reach a diameter of 4 mm ± 1 mm, while the stainless steel IUD resulted in artifacts measuring 200mm ± 10 mm when using gradient echo pulse sequences.

conclusionsStandard IUDs (copper/gold) can be considered as conditional for MR safety at 1.5 T and 3.0 T, demonstrating at wbSAR up to 4W/kg and a magnetic field gradient of up to 40T/m with minimal imaging artifacts. The stainless steel IUD, however, induces unacceptable artifacts and is potentially harmful to patients during MRI due to high magnetic dislocation forces and torque (MR unsafe).

Indexed as

ArtifactsFemaleGoldHumansIntrauterine DevicesIntrauterine Devices, CopperMagnetic Resonance ImagingStainless SteelTorqueGoldStainless Steel

Identifiers

PMID30300364
PMCPMC6177157
OpenAlexW2897997912

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.