Evidence map›Paper›PMID 30294895›Full record

ArticleBiotechnology progress2018

Data-driven multi-objective optimization via grid compatible simplex technique and desirability approach for challenging high throughput chromatography applications.

Spyridon Konstantinidis, John P Welsh, Nigel J Titchener-Hooker, David J Roush, Ajoy Velayudhan

Abstract read
In one paragraph

Article in Biotechnology progress, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Spyridon KonstantinidisDept. of Biochemical Engineering, The Advanced Centre for Biochemical Engineering, University College London, London, U.K.ORCID 0000-0001-7227-5853
John P WelshBiologics Process Research and Development, Merck & Co., Inc., Kenilworth, NJ, USA.
Nigel J Titchener-HookerDept. of Biochemical Engineering, The Advanced Centre for Biochemical Engineering, University College London, London, U.K.
David J RoushBiologics Process Research and Development, Merck & Co., Inc., Kenilworth, NJ, USA.
Ajoy VelayudhanDept. of Biochemical Engineering, The Advanced Centre for Biochemical Engineering, University College London, London, U.K.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recently, a grid compatible Simplex variant has been demonstrated to identify optima consistently and rapidly in challenging high throughput (HT) applications in early bioprocess development. Here, this method is extended by deploying it to multi-objective optimization problems. Three HT chromatography case studies are presented, each posing challenging early development situations and including three responses which were amalgamated by the adoption of the desirability approach. The suitability of a design of experiments (DoE) methodology per case study, using regression analysis in addition to the desirability approach, was evaluated for a large number of weights and in the presence of stringent and lenient performance requirements. Despite the adoption of high-order models, this approach had low success in identification of the optimal conditions. For the deployment of the Simplex approach, the deterministic specification of the weights of the merged responses was avoided by including them as inputs in the formulated multi-objective optimization problem, facilitating this way the decision making process. This, and the ability of the Simplex method to locate optima, rendered the presented approach highly successful in delivering rapidly operating conditions, which belonged to the Pareto set and offered a superior and balanced performance across all outputs compared to alternatives. Moreover, its performance was relatively independent of the starting conditions and required sub-minute computations despite its higher order mathematical functionality compared to DoE techniques. These evidences support the suitability of the grid compatible Simplex method for early bioprocess development studies involving complex data trends over multiple responses. © 2018 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 34:1393-1406, 2018.

Indexed as

AlgorithmsBiotechnologyChromatographyHigh-Throughput Screening Assayschromatographydesign of experimentsdesirabilityhigh throughput bioprocess developmentmulti-objective optimizationPareto frontSimplex optimization

Identifiers

PMID30294895
PMCPMC6585819

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.