Observational studyBMC musculoskeletal disorders2018
Intra and interrater reliability and clinical feasibility of a simple measure of cervical movement sense in patients with neck pain.
Observational study in BMC musculoskeletal disorders, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Effects of a Single Dry Needling Session of the Obliquus Capitis Inferior on the Altered Sensorimotor Function in People With Neck Pain: a Random Control Trial
Evaluation of Cervical Position and Movement Sense Using Computer Vision Technology in Healthy Individuals
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it, 32 citations in OpenAlex.
- Head kinematics in patients with neck pain compared to asymptomatic controls: a systematic review.BMC musculoskeletal disorders · 2022Pooled it
- Immediate effects of upper cervical spinal manipulation on cervical sensorimotor control in individuals with chronic primary cervical pain: an exploratory randomized controlled trial.Chiropractic & manual therapies · 2026Trial
- Effects of dry needling of the obliquus capitis inferior on sensorimotor control and cervical mobility in people with neck pain: A double-blind, randomized sham-controlled trial.Brazilian journal of physical therapyTrial
- Validity and Reliability of an Immersive Virtual Reality System for Multidimensional Assessment of Cervical Sensorimotor Control: Cross-Sectional Study.JMIR rehabilitation and assistive technologies · 2026Article
- Effects of Dry Needling of the Obliquus Capitis Inferior in Patients with Cervicogenic Headache and Upper Cervical Dysfunction: An Exploratory Randomized Sham-Controlled Trial.Journal of clinical medicine · 2025Article
- Postural and cervical proprioceptive implications in adult humans with ankyloglossia: an observational study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Observational
- Impaired cervical proprioception in patients with lateral epicondylitis: a case-control study.BMC musculoskeletal disorders · 2025Article
- Reliability and measurement error of sensorimotor tests in patients with neck pain: a systematic review.Archives of physiotherapy · 2023Review
- Proprioceptive Disturbance in Chronic Neck Pain: Discriminate Validity and Reliability of Performance of the Clinical Cervical Movement Sense Test.Frontiers in pain research (Lausanne, Switzerland) · 2022Article
- HeadUp: A Low-Cost Solution for Tracking Head Movement of Children with Cerebral Palsy Using IMU.Sensors (Basel, Switzerland) · 2021Article
- German version of the Chedoke McMaster arm and hand activity inventory (CAHAI-G): intra-rater reliability and responsiveness.Health and quality of life outcomes · 2020Article
- Article
- Article
- Multidimensional machine learning approach for classifying patients with neck pain based on movement control test.Brazilian journal of physical therapyArticle
- Trunk-head coordination in chronic neck pain, reliability, influence of visual feedback, and relationship to patient-reported outcomes.Archives of physiotherapyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPattern tracing tasks can be used to assess cervical spine movement sense (CMS). A simple clinical measure of CMS (tracing fixed figure-of-eight (F8) and zigzag (ZZ) patterns with a head mounted laser) has been proposed and assessed in asymptomatic subjects. It is important to determine if examiner ratings of the traces are reliable and feasible for clinical use in those with neck pain. We therefore examined the intra- and inter-rater reliability of rating video recordings of the CMS tasks, and the feasibility of undertaking the tests in clinic by comparing slow motion versus real-time video ratings.
methodsCross-sectional study examining neck pain subjects from a physiotherapy clinic. F8 and ZZ patterns traced with a head-mounted laser pointer at two velocities (accurate; accurate & fast) were videoed and later examined. Time (total time taken to complete the pattern), error frequency (number of deviations) and error magnitude (sum of deviations multiplied by distance from the central line) were measured. Two assessors independently evaluated the laser tracing videos in slow motion; a third rated the videos in real time. Intraclass correlation coefficients (ICC) and standard error of measurements (SEM) were calculated for intra- and inter-tester reliability, and feasibility.
resultsTwenty neck pain patient (13 women) videos were assessed. Intra-and inter-rater reliability was substantial to almost-perfect (ICC 0.76-1.00; SEM < 0.01-2.50). Feasibility was moderate to almost-perfect (ICC 0.54-1; SEM < 0.01-2.98).
conclusionsVideo (slow motion) ratings of time and errors for F8 and ZZ movement patterns in neck pain subjects showed high intra and inter-rater reliability. Achieving reliable ratings in clinic (real-time) appears feasible. Synthesising our results, the most reliable and feasible CMS ratings appear to be when the subject uses accurate rather than accurate and fast execution. The ZZ movement pattern may be superior to F8 in terms of rating. Time and error frequency for tracing F8 and ZZ as accurately as possible in determining CMS appears promising for use in clinic. Future research directions were identified.
Indexed as
Identifiers
What OpenQuestion holds