Trial reportMedicine2018
Comparison of blind intubation via supraglottic airway devices versus standard intubation during different airway emergency scenarios in inexperienced hand: Randomized, crossover manikin trial.
Trial report in Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.
- Pooled it
- Cardiopulmonary resuscitation (CPR) during spaceflight - a guideline for CPR in microgravity from the German Society of Aerospace Medicine (DGLRM) and the European Society of Aerospace Medicine Space Medicine Group (ESAM-SMG).Scandinavian journal of trauma, resuscitation and emergency medicine · 2020Guideline
- Novel airway device Vie Scope in several pediatric airway scenario: A randomized simulation pilot trial.Medicine · 2020Trial
- Analysis of endotracheal intubation-related judicial precedents in South Korea.Korean journal of anesthesiology · 2021Article
- A prospective observational study comparing two supraglottic airway devices in out-of-hospital cardiac arrest.BMC emergency medicine · 2021Observational
- Conversion of I-gel to definitive airway in a cervical immobilized manikin: Aintree intubation catheter vs long endotracheal tube.BMC anesthesiology · 2020Article
- Comparison of i-Gel as a Conduit for Intubation between under Fiberoptic Guidance and Blind Endotracheal Intubation during Cardiopulmonary Resuscitation: A Randomized Simulation Study.Emergency medicine international · 2019Article
- Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim.Emergency medicine international · 2019Article
- Comparison of Different Intubation Methods in Difficult Airways during Simulated Cardiopulmonary Resuscitation with Continuous Chest Compression: A Randomized Cross-Over Manikin Trial.Emergency medicine international · 2019Article
- Comparison of three supraglottic airway devices for blind tracheal intubation by novice practitioners: A randomized manikin study.Turkish journal of emergency medicineArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 8 institutions in 5 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSecuring the airway and enabling adequate oxygenation and ventilation is essential during cardiopulmonary resuscitation (CPR). The aim of the study was to evaluate the success rate of blind intubation via the I-Gel and the Air-Q compared with direct laryngoscopy guided endotracheal intubation by inexperienced physician and to measure time to successful intubation.
methodsThe study was designed as a randomized, cross-over simulation study. A total of 134 physicians, from specialties other than Anesthesia or Emergency Medicine, who considered themselves skilled in endotracheal intubation but who have never used any kind of supraglottic airway device performed blind intubation via the I-Gel and Air-Q and direct laryngoscopy guided endotracheal intubation in 3 randomized scenarios: normal airway without chest compression during intubation attempt; normal airway with continuous chest compression during intubation attempt; difficult airway with continuous chest compression.
resultsScenario A: Success rate with initial intubation attempt was 72% for endotracheal intubation, 75% in Air-Q, and 81% in I-Gel. Time to endotracheal intubation and ease of intubation was comparable with all 3 airway devices used. Scenario B: Success rate with the initial intubation attempt was 42% for endotracheal intubation, compared with 75% in Air-Q and 80% in I-Gel. Time for endotracheal intubation was significantly prolonged in endotracheal intubation (42 seconds, 35-49), compared with Air-Q (21 seconds, 18-32) and I-Gel (19 seconds, 17-27). Scenario C: The success rate with the initial intubation attempt was 23% in endotracheal intubation, compared with 65% in Air-Q and 74% in I-Gel. Time to intubation was comparable with both supraglottic airway devices (20 vs 22 seconds) but was significantly shorter compared with endotracheal intubation (50 seconds, P < .001).
conclusionsLess to moderately experienced providers are able to perform endotracheal intubation in easy airways but fail during ongoing chest compressions and simulated difficult airway. Consequently, less to moderately experienced providers should refrain from endotracheal intubation during ongoing chest compressions during CPR and in expected difficult airways. Supraglottic airway devices are reliable alternatives and blind intubation through these devices is a valuable airway management strategy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.