Evidence map›Paper›PMID 30288605›Full record

ArticleClinical oral investigations2019

Stress distribution in mandibular donor site after harvesting bone grafts of various sizes from the ascending ramus of a dentate mandible by finite element analysis.

Stephan Christian Möhlhenrich, Kristian Kniha, József Szalma, Nassim Ayoub, Frank Hölzle, Michael Wolf, Ali Modabber, Stefan Raith

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. [Biomechanical study of cystic lesions of the mandible based on a three-dimensional finite element model].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Stephan Christian MöhlhenrichDepartment of Orthodontics and Dentofacial Orthopedics, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany. smoehlhenrich@ukaachen.de.
Kristian KnihaDepartment of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
József SzalmaDepartment of Oral and Maxillofacial Surgery, University of Pecs, Dischka Győző str. 5, Pecs, 7621, Hungary.
Nassim AyoubDepartment of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
Frank HölzleDepartment of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
Michael WolfDepartment of Orthodontics and Dentofacial Orthopedics, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
Ali ModabberDepartment of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
Stefan RaithDepartment of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
Universitätsklinikum Aachen · DERWTH Aachen University · DEUniversity of Pecs · HU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeHarvesting bone from the ascending ramus of the mandible is a common procedure. However, mandibular fracture may occur after grafting bone blocks. This study aimed to investigate the resulting force distribution of stress and strain in the mandibular donor site after harvesting bone grafts of different sizes and various loadings.

methodsFinite element analysis was performed for virtual harvesting of bone blocks of nine different sizes between 15 × 20 and 25 × 30 mm and three different chewing loads (incisal, ipsilateral and contralateral). von Mises stress and first principal stress distributions were measured.

resultsvon Mises stress was distributed between 35.01 (10 × 15 mm graft, incisal load) and 333.25 MPa (30 × 20 mm graft ipsilateral load), whereas first principal stress distributions were between 48.27 (10 × 15 mm graft, incisal load) and 414.69 MPa (30 × 20 mm graft ipsilateral load). In general, the least stress was observed with incisal load followed by ipsilateral load and finally contralateral load. The critical value of 133 MPa was found after removing almost all grafts with a width of 20 or 30 mm.

conclusionsIncisal loading led to less stress compared with contralateral and ipsilateral loads. Increasing graft size led to increasing weakness of the donor site. Graft width exerted a greater influence on stress development than its height. CLINICAL RELEVANCE: Ipsilateral chewing and increasing width of the bone graft result in maximum stress in the mandibular donor side, and critical values regarding to the possibility of fractures are already to expect from a graft size of 20 × 15 mm.

Indexed as

Bone TransplantationDental Stress AnalysisModels, DentalStress, MechanicalAdultBite ForceFinite Element AnalysisHumansJaw FracturesMaleMandibleSoftwareTomography, X-Ray ComputedChewing loadDentate mandibleFinite element analysisMandibular donor siteStress distribution

Identifiers

PMID30288605
OpenAlexW2895073681

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.