Evidence map›Paper›PMID 30288243›Full record

ArticleChemical science2018

Phosphorescent iridium(iii) complexes capable of imaging and distinguishing between exogenous and endogenous analytes in living cells.

Kenneth Yin Zhang, Taiwei Zhang, Huanjie Wei, Qi Wu, Shujuan Liu, Qiang Zhao, Wei Huang

Open access · diamondAbstract read
In one paragraph

Article in Chemical science, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
4.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 56 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Effective Long Afterglow Amplification Induced by Surface Coordination Interaction.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Kenneth Yin ZhangKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.
Taiwei ZhangKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.
Huanjie WeiKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.
Qi WuKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.
Shujuan LiuKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.
Qiang ZhaoKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.ORCID 0000-0002-3788-4757
Wei HuangKey Laboratory for Organic Electronics and Information Displays and Jiangsu Key Laboratory for Biosensors , Institute of Advanced Materials (IAM) , Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing University of Posts & Telecommunications , 9 Wenyuan Road , Nanjing 210023 , P. R. China . Email: iamqzhao@njupt.edu.cn ; Email: wei-huang@njtech.edu.cn.ORCID 0000-0001-7004-6408
Nanjing University of Posts and Telecommunications · CNNorthwestern Polytechnical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many luminescent probes have been developed for intracellular imaging and sensing. During cellular luminescence sensing, it is difficult to distinguish species generated inside cells from those internalized from extracellular environments since they are chemically the same and lead to the same luminescence response of the probes. Considering that endogenous species usually give more information about the physiological and pathological parameters of the cells while internalized species often reflect the extracellular environmental conditions, we herein reported a series of cyclometalated iridium(iii) complexes as phosphorescent probes that are partially retained in the cell membrane during their cellular uptake. The utilization of the probes for sensing and distinguishing between exogenous and endogenous analytes has been demonstrated using hypoxia and hypochlorite as two examples of target analytes. The endogenous analytes lead to the luminescence response of the intracellular probes while the exogenous analytes are reported by the probes retained in the cell membrane during their internalization.

Identifiers

PMID30288243
PMCPMC6148462
OpenAlexW2887786172

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked