ArticleThe international journal of cardiovascular imaging2019
Low CT temporal sampling rates result in a substantial underestimation of myocardial blood flow measurements.
Article in The international journal of cardiovascular imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Protocol optimization and myocardial blood flow quantification in dynamic myocardial perfusion CT-where do we stand?European radiology · 2025Article
- State of the art of CT myocardial perfusion.La Radiologia medica · 2025Review
- Article
- Reproducibility of a single-volume dynamic CT myocardial blood flow measurement technique: validation in a swine model.European radiology experimental · 2024Article
- Dynamic CT Myocardial Perfusion: The Role of Functional Evaluation in the Diagnosis of Coronary Artery Disease.Journal of clinical medicine · 2023Review
- Low-dose quantitative CT myocardial flow measurement using a single volume scan: phantom and animal validation.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- Dynamic myocardial CT perfusion imaging-state of the art.European radiology · 2023Review
- Knowledge of Hyperemic Myocardial Blood Flow in Healthy Subjects Helps Identify Myocardial Ischemia in Patients With Coronary Artery Disease.Frontiers in cardiovascular medicine · 2022Article
- Combining perfusion and angiography with a low-dose cardiac CT technique: a preliminary investigation in a swine model.The international journal of cardiovascular imaging · 2021Article
- Computed tomography for myocardial characterization in ischemic heart disease: a state-of-the-art review.European radiology experimental · 2020Review
- Cardiovascular imaging 2019 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2020Article
- Imaging of coronary flow capacity: is there a role for dynamic CT perfusion imaging?European journal of nuclear medicine and molecular imaging · 2019Article
- Cardiovascular imaging 2018 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2019Article
- Timing optimization of low-dose first-pass analysis dynamic CT myocardial perfusion measurement: validation in a swine model.European radiology experimental · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this study was to evaluate the effect of temporal sampling rate in dynamic CT myocardial perfusion imaging (CTMPI) on myocardial blood flow (MBF). Dynamic perfusion CT underestimates myocardial blood flow compared to PET and SPECT values. For accurate quantitative analysis of myocardial perfusion with dynamic perfusion CT a stable calibrated HU measurement of MBF is essential. Three porcine hearts were perfused using an ex-vivo Langendorff model. Hemodynamic parameters were monitored. Dynamic CTMPI was performed using third generation dual source CT at 70 kVp and 230-350 mAs/rot in electrocardiography(ECG)-triggered shuttle-mode (sampling rate, 1 acquisition every 2-3 s; z-range, 10.2 cm), ECG-triggered non-shuttle mode (fixed table position) with stationary tube rotation (1 acquisition every 0.5-1 s, 5.8 cm), and non-ECG-triggered continuous mode (1 acquisition every 0.06 s, 5.8 cm). Stenosis was created in the circumflex artery, inducing different fractional flow reserve values. Volume perfusion CT Myocardium software was used to analyze ECG-triggered scans. For the non-ECG triggered scans MASS research version was used combined with an in-house Matlab script. MBF (mL/g/min) was calculated for non-ischemic segments. True MBF was calculated using input flow and heart weight. Significant differences in MBF between shuttle, non-shuttle and continuous mode were found, with median MBF of 0.87 [interquartile range 0.72-1.00], 1.20 (1.07-1.30) and 1.65 (1.40-1.88), respectively. The median MBF in shuttle mode was 56% lower than the true MBF. In non-shuttle and continuous mode, the underestimation was 41% and 18%. Limited temporal sampling rate in standard dynamic CTMPI techniques contributes to substantial underestimation of true MBF.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.