Evidence map›Paper›PMID 30284052›Full record

ArticleJournal of medical systems2018

Multilayered Deep Structure Tensor Delaunay Triangulation and Morphing Based Automated Diagnosis and 3D Presentation of Human Macula.

Taimur Hassan, M Usman Akram, Mahmood Akhtar, Shoab Ahmad Khan, Ubaidullah Yasin

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

Taimur HassanDepartment of Computer & Software Engineering, National University of Sciences and Technology (NUST), Islamabad, 44000, Pakistan.
M Usman AkramDepartment of Computer & Software Engineering, National University of Sciences and Technology (NUST), Islamabad, 44000, Pakistan. usmakram@gmail.com.ORCID http://orcid.org/0000-0002-6208-7231
Mahmood AkhtarSchool of Civil and Environmental Engineering's Research Centre for Integrated Transport Innovation (rCITI), University of New South Wales, Sydney, Australia.
Shoab Ahmad KhanDepartment of Computer & Software Engineering, National University of Sciences and Technology (NUST), Islamabad, 44000, Pakistan.
Ubaidullah YasinDepartment of Ophthalmology, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan.
National University of Sciences and Technology · PKArmed Forces Institute of Pathology · PKBahria University · PKUNSW Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Maculopathy is the group of diseases that affects central vision of a person and they are often associated with diabetes. Many researchers reported automated diagnosis of maculopathy from optical coherence tomography (OCT) images. However, to the best of our knowledge there is no literature that presents a complete 3D suite for the extraction as well as diagnosis of macula. Therefore, this paper presents a multilayered convolutional neural networks (CNN) structure tensor Delaunay triangulation and morphing based fully autonomous system that extracts up to nine retinal and choroidal layers along with the macular fluids. Furthermore, the proposed system utilizes the extracted retinal information for the automated diagnosis of maculopathy as well as for the robust reconstruction of 3D macula of retina. The proposed system has been validated on 41,921 retinal OCT scans acquired from different OCT machines and it significantly outperformed existing state of the art solutions by achieving the mean accuracy of 95.27% for extracting retinal and choroidal layers, mean dice coefficient of 0.90 for extracting fluid pathology and the overall accuracy of 96.07% for maculopathy diagnosis. To the best of our knowledge, the proposed framework is first of its kind that provides a fully automated and complete 3D integrated solution for the extraction of candidate macula along with its fully automated diagnosis against different macular syndromes.

Indexed as

Neural Networks, ComputerHumansResearch DesignRetinaRetinal DiseasesTomography, Optical CoherenceImage processingNeural networksOphthalmologyOptical coherence tomographyPattern recognition

Identifiers

PMID30284052
OpenAlexW2895454497

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.