Evidence map›Paper›PMID 30281614›Full record

ArticlePloS one2018

Automated tube voltage selection in pediatric non-contrast chest CT.

Azadeh Hojreh, Peter Homolka, Jutta Gamper, Sylvia Unterhumer, Daniela Kienzl-Palma, Csilla Balassy, Thomas Wrba, Helmut Prosch

Abstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Azadeh HojrehDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-4556-1931
Peter HomolkaCentre for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Jutta GamperCentre for Medical Statistics, Informatics and Intelligent Systems, Medical University of Vienna, Vienna, Austria.
Sylvia UnterhumerDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-0505-4919
Daniela Kienzl-PalmaDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
Csilla BalassyDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.ORCID 0000-0003-0107-3327
Thomas WrbaIT-Systems & Communications, IT4Science, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-4915-4620
Helmut ProschDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundModern CT scanners provide automatic dose adjustment systems, which are promising options for reducing radiation dose in pediatric CT scans. Their impact on patient dose, however, has not been investigated sufficiently thus far.

objectiveTo evaluate automated tube voltage selection (ATVS) in combination with automated tube current modulation (ATCM) in non-contrast pediatric chest CT, with regard to the diagnostic image quality. MATERIALS AND

methodsThere were 160 non-contrast pediatric chest CT scans (8.7±5.4 years) analyzed retrospectively without and with ATVS. Correlations of volume CT Dose Index (CTDIvol) and effective diameter, with and without ATVS, were compared using Fisher's z-transformation. Image quality was assessed by mean signal-difference-to-noise ratios (SDNR) in the aorta and in the left main bronchus using the independent samples t-test. Two pediatric radiologists and a general radiologist rated overall subjective Image quality. Readers' agreement was assessed using weighted kappa coefficients. A p value <0.05 was considered significant.

resultsCTDIvol correlation with the effective diameter was r = 0.62 without and r = 0.80 with ATVS (CI: -0.04 to -0.60; p = 0.025). Mean SDNR was 10.88 without and 10.03 with ATVS (p = 0.0089). Readers' agreement improved with ATVS (weighted kappa between pediatric radiologists from 0.1 (0.03-0.16) to 0.27 (0.09-0.45) with ATVS; between general and each pediatric radiologist from 0.1 (0.06-0.14) to 0.12 (0.05-0.20), and from 0.22 (0.11-0.34) to 0.36 (0.24-0.49)).

conclusionATVS, combined with ATCM, results in a radiation dose reduction for pediatric non-contrast chest CT without a loss of diagnostic image quality and prevents errors in manual tube voltage setting, and thus protecting larger children against an unnecessarily high radiation exposure.

Indexed as

AlgorithmsChildContrast MediaFemaleHumansMaleRadiation DosageRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSignal-To-Noise RatioThoraxTomography, X-Ray ComputedContrast Media

Identifiers

PMID30281614
PMCPMC6169939

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.