The potential impact of ultrathin filter design on dosimetry and relative biological effectiveness in modern image-guided small animal irradiators.

Yannick Poirier, Christopher Daniel Johnstone, Charles Kirkby

Abstract read
In one paragraph

Article in The British journal of radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Yannick Poirier1 Department of Radiation Oncology, Division of Translational Radiation Sciences, University of Maryland School of Medicine , Baltimore, MD , USA.
Christopher Daniel Johnstone1 Department of Radiation Oncology, Division of Translational Radiation Sciences, University of Maryland School of Medicine , Baltimore, MD , USA.
Charles Kirkby4 Department of Medical Physics, Jack Ady Cancer Center , Lethbridge, AB , Canada.
University of Calgary · CAUniversity of Maryland, Baltimore · USUniversity of Victoria · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objective: Modern image-guided small animal irradiators like the Xstrahl Small Animal Radiation Research Platform (SARRP) are designed with ultrathin 0.15 mm Cu filters, which compared with more heavily filtrated traditional cabinet-style biological irradiators, produce X-ray spectra weighted toward lower energies, impacting the dosimetric properties and the relative biological effectiveness (RBE). This study quantifies the effect of ultrathin filter design on relative depth dose profiles, absolute dose output, and RBE using Monte Carlo techniques.

methods: The percent depth-dose and absolute dose output are calculated using kVDoseCalc and EGSnrc, respectively, while a tally based on the induction of double-strand breaks as a function of electron spectra invoked in PENELOPE is used to estimate the RBE.

results: The RBE increases by >2.4% in the ultrathin filter design compared to a traditional irradiator. Furthermore, minute variations in filter thickness have notable effects on the dosimetric properties of the X-ray beam, increasing the percent depth dose (at 2 cm in water) by + 0.4%/0.01 mm Cu and decreasing absolute dose (at 2 cm depth in water) by -1.8%/0.01 mm Cu for the SARRP.

conclusions: These results show that modern image-guided irradiators are quite sensitive to small manufacturing variations in filter thickness, and show a small change in RBE compared to traditional X-ray irradiators. ADVANCES IN KNOWLEDGE:: We quantify the consequences of ultrathin filter design in modern image-guided biological irradiators on relative and absolute dose, and RBE. Our results show these to be small, but not insignificant, suggesting laboratories transitioning between irradiators should carefully design their radiobiological experiments.

Indexed as

AnimalsEquipment DesignRadiobiologyRadiometryRadiotherapy, Image-GuidedRelative Biological Effectiveness

Identifiers

PMID30281330
PMCPMC6541192
OpenAlexW2895004169

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.