Evidence map›Paper›PMID 30281130›Full record

ReviewNephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association2018

Membrane innovation: closer to native kidneys.

Markus Storr, Richard A Ward

Abstract readReview
In one paragraph

Review in Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Increasing the Removal of Large Solutes by Kidney Replacement Therapy.Journal of the American Society of Nephrology : JASN · 2025
    Review
  5. Article
  6. Investigation of the inhibition of bacteria and endotoxin influx by back filtration through dialyzer membranes.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2024
    Article
  7. Review
  8. Review
  9. Expanded hemodialysis: what's up, Doc?Clinical kidney journal · 2023
    Review
  10. Article
  11. Review
  12. Review
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. OxonePolymers · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Markus StorrBaxter International, Research and Development, Hechingen, Germany.
Richard A WardNelson, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Modern methods in analytical biochemistry have established that uraemia is associated with the retention of proteins, both in their native state and post-translationally modified, over a wide range of molecular weights up to 60 kDa. Evidence is accumulating that these higher molecular weight retention solutes are important uraemic toxins, and therapies such as online haemodiafiltration (HDF), which enhance their removal, are associated with improved outcomes. However, HDF has limitations regarding cost, clinical implementation and the need for an external source of sterile substitution solution to maintain fluid balance. New membranes that have a solute removal profile more closely approaching that of the glomerular filtration barrier when used for conventional haemodialysis, while at the same time not allowing the passage of clinically significant amounts of beneficial proteins, are needed to address these limitations. Tighter control of the molecular characteristics of the polymers used for membrane fabrication, along with the introduction of additives and improvements in the manufacturing process, has led to membranes with a tighter pore size distribution that allows the use of an increased absolute pore size without leaking substantial amounts of albumin. At the same time, the wall thickness and internal diameter of membrane fibres have been decreased, enhancing convective transport within the dialyser without the need for an external source of substitution solution. These new expanded range membranes provide a solute removal profile more like that of the native kidney than currently available membranes when used in conventional haemodialysis.

Indexed as

Membranes, ArtificialAlbuminsAnimalsHemodiafiltrationHumansMolecular WeightRenal DialysisRenal InsufficiencyToxins, BiologicalAlbuminsMembranes, ArtificialToxins, Biological

Identifiers

PMID30281130
PMCPMC6168921

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.