Evidence map›Paper›PMID 30280331›Full record

ArticleMedical & biological engineering & computing2019

Head-mounted interface for intuitive vision control and continuous surgical operation in a surgical robot system.

Nhayoung Hong, Myungjoon Kim, Chiwon Lee, Sungwan Kim

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nhayoung HongInterdisciplinary Program for Bioengineering, Graduate School, Seoul National University, Seoul, 03080, Republic of Korea.
Myungjoon KimKorea Electrotechnology Research Institute, Ansan, 15588, Republic of Korea.
Chiwon LeeKorea Electrotechnology Research Institute, Ansan, 15588, Republic of Korea.
Sungwan KimInstitute of Medical and Biological Engineering, Seoul National University, Seoul, 08826, Republic of Korea. sungwan@snu.ac.kr.

Funding

Intuitive Surgical (US) da Vinci Research KitNational Research Foundation of Korea (KR) Grant 2017R1A2B2006163
6 · The paper itself

Abstract

Although robot-assisted surgeries offer various advantages, the discontinuous surgical operation flow resulting from switching the control between the patient-side manipulators and the endoscopic robot arm can be improved to enhance the efficiency further. Therefore, in this study, a head-mounted master interface (HMI) that can be implemented to an existing surgical robot system and allows continuous surgical operation flow using the head motion is proposed. The proposed system includes an HMI, a four degrees of freedom endoscope control system, a simple three-dimensional endoscope, and a da Vinci Research Kit. Eight volunteers performed seven head movements and their data from HMI was collected to perform support vector machine (SVM) classification. Further, ten-fold cross-validation was performed to optimize its parameters. Using the ten-fold cross-validation result, the SVM classifier with the Gaussian kernel (σ = 0.85) was chosen, which had an accuracy of 92.28%. An endoscopic control algorithm was developed using the SVM classification result. A peg transfer task was conducted to check the time-related effect of HMI's usability on the system, and the paired t test result showed that the task completion time was reduced. Further, the time delay of the system was measured to be 0.72 s. Graphical abstract A head-mounted master interface (HMI), which can be implemented to an existing surgical robot system, was developed to allow simultaneous surgical operation flow. The surgeon's head motion is detected through the proposed HMI and classified using a support vector machine to manipulate the endoscopic robotic arm. A classification accuracy of 92.28% was achieved.

Indexed as

SurgeonsEndoscopyEquipment DesignHeadHumansLaparoscopyMinimally Invasive Surgical ProceduresMotionReproducibility of ResultsRobotic Surgical ProceduresTime FactorsVision, Ocularda Vinci Research KitEndoscopic control interfaceHead movementMachine learningMinimally invasive surgical procedure

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.