Evidence map›Paper›PMID 30279032›Full record

ArticleUltrasound in medicine & biology2018

Integrated Histotripsy and Bubble Coalescence Transducer for Thrombolysis.

Aiwei Shi, Jonathan Lundt, Zilin Deng, Jonathan Macoskey, Hitinder Gurm, Gabe Owens, Xi Zhang, Timothy L Hall, Zhen Xu

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Ultrasound-Guided Intravascular Sonothrombolysis With a Dual Mode Ultrasound Catheter: In Vitro Study.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  8. Article
  9. Dual-Frequency Intravascular Sonothrombolysis: An In Vitro Study.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  10. Image-Guided High-Intensity Focused Ultrasound, A Novel Application for Interventional Nuclear Medicine?Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2021
    Review
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Scan Parameter Optimization for Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020
    Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Aiwei ShiDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA. Electronic address: aiweishi@umich.edu.
Jonathan LundtDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Zilin DengDepartment of Biomedical Engineering, Beihang University, Beijing, China.
Jonathan MacoskeyDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Hitinder GurmDepartment of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA.
Gabe OwensDivision of Pediatric Cardiology, Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan, USA.
Xi ZhangFitbit Corporation, San Francisco, California, USA.
Timothy L HallDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Zhen XuDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Division of Pediatric Cardiology, Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan, USA.

Funding

Image-Guided Non-Invasive Ultrasonic Thrombolysis Using HistotripsyR01EB008998 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI XU, ZHEN · 2008 to 2017
$4.5M
Novel, Noninvasive, Rapid Tumor Ablation Technology using HistotripsyR01CA211217 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI XU, ZHEN · 2018 to 2022
$2.7M
Novel Ultrasonic Technology to Treat Hemorrhagic StrokeR21NS093121 · NINDS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI XU, ZHEN · 2015 to 2016
$426k
NCI NIH HHS R01 CA211217NIBIB NIH HHS R01 EB008998NINDS NIH HHS R21 NS093121
6 · The paper itself

Abstract

After the collapse of a cavitation bubble cloud, residual microbubbles can persist for up to seconds and function as weak cavitation nuclei for subsequent pulses in a phenomenon known as cavitation memory effect. In histotripsy, the cavitation memory effect can cause bubble clouds to repeatedly form at the same discrete set of sites. This effect limits the efficacy of histotripsy-based tissue fractionation. Our previous studies have indicated that low-amplitude bubble-coalescing (BC) ultrasound sequences interleaved with high-amplitude histotripsy pulses can coalesce the residual bubbles into one large bubble quickly. This reduces the cavitation memory effect and may increase treatment efficacy. Histotripsy has been investigated for thrombolysis by breaking up clots into debris smaller than red blood cells. However, this treatment has low efficacy for aged or retracted clots. In this study, we investigate the use of histotripsy with BC to improve the efficacy of treatment of retracted clots. An integrated histotripsy and bubble-coalescing (HBC) transducer system with specialized electronic driving system was built in-house. One high-amplitude (32 MPa), one-cycle histotripsy pulse followed by 36 low-amplitude (2.4 MPa), one-cycle BC pulses formed one HBC sequence. Results indicate that HBC sequences successfully generated a flow channel through the retracted clots at scan speeds of 0.2-0.5 mm/s. The channel size created using the HBC sequence was 128% to 480% larger than that created using histotripsy alone. The clot debris particles generated during HBC treatments were within the tolerable range. These results illustrate the concept that BC improves the treatment efficacy of histotripsy thrombolysis for retracted clots.

Indexed as

Femoral VeinMicrobubblesTransducersAnimalsHigh-Intensity Focused Ultrasound AblationIn Vitro TechniquesPhantoms, ImagingThrombosisBubble coalescenceCavitation memory effectHistotripsyRetracted clotSonothrombolysisThrombolysis

Identifiers

PMID30279032
PMCPMC6215517

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.