Evidence map›Paper›PMID 30276205›Full record

ArticleBioMed research international2018

Application of 3D-Printed Personalized Guide in Arthroscopic Ankle Arthrodesis.

Xiaojun Duan, Peng He, Huaquan Fan, Chengchang Zhang, Fuyou Wang, Liu Yang

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03626935 (3D Printed Customized Guide in Ankle Arthrodesis), which is not on this map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03626935 naunknown statusnot on this map

3D Printed Customized Guide in Ankle Arthrodesis

TypeinterventionalSponsorSouthwest Hospital, ChinaRan2014 to 2019Enrolled10ConditionsAnkle InjuriesArms3D-printed customized guide plate
3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 27 citations in OpenAlex.

  1. Pooled it
  2. Application of patient-specific surgical guides in foot and ankle surgery.Acta orthopaedica et traumatologica turcica · 2025
    Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Carpal bone replacement using personalized 3D printed tantalum prosthesis.Frontiers in bioengineering and biotechnology · 2023
    Article
  9. Article
  10. The Surgical Treatment of Osteoarthritis.Life (Basel, Switzerland) · 2022
    Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Xiaojun DuanCenter for Joint Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China.ORCID 0000-0001-7644-2452
Peng HeChongqing Institute of Optics and Machines, Chongqing 401122, China.
Huaquan FanCenter for Joint Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China.
Chengchang ZhangCenter for Joint Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China.
Fuyou WangCenter for Joint Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China.
Liu YangCenter for Joint Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China.
Army Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo accurately drill the Kirschner wire with the help of the 3D-printed personalized guide and to evaluate the feasibility of the 3D technology as well as the outcome of the surgery.

methodsPatients' DICM data of ankle via CT examinations were introduced into the MIMICS software to design the personalized guides. Two 2mm Kirschner wires were drilled with the help of the guides; the C-arm fluoroscopy was used to confirm the position of the wires before applying the cannulated screws. The patients who underwent ankle arthrodesis were divided into two groups. The experimental group adopted the 3D-printed personalized guides, while the control group received traditional method, i.e., drilling the Kirschner wires according to the surgeon's previous experience. The times of completing drilling the Kirschner wires to correct position were compared between the two groups. Regular follow-ups were conducted to statistically analyze the differences in the ankle fusion time and AOFAS scores between the two groups.

results3D-printed personalized guides were successfully prepared. A total of 29 patients were enrolled, 15 in the experimental group and 14 in the control group. It took 2.2 ± 0.8 minutes to drill the Kirschner wires to correct position in the experimental group and 4.5 ± 1.6 minutes in the control group (

conclusionsThe application of 3D-printed personalized guide in assisting the accurate drilling of Kirschner wire in ankle arthrodesis can shorten the operation time and reduce the intraoperative radiation. This technique does not affect the surgical outcome. TRIAL REGISTRATION NUMBER: This study is registered on www.clinicaltrials.gov with NCT03626935.

Indexed as

ArthrodesisBone WiresPrinting, Three-DimensionalAdultAgedAnkleFemaleFollow-Up StudiesHumansMaleMiddle AgedTalusTreatment Outcome

Identifiers

PMID30276205
PMCPMC6157116
OpenAlexW2891399962

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials