ArticleInternational journal of spine surgery2018
Polyetheretherketone (PEEK) Rods for Lumbar Fusion: A Systematic Review and Meta-Analysis.
Article in International journal of spine surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2023Pooled it
- Evaluation of Screw Loosening in Patients Undergoing Semi-rigid Stabilization with Polyetheretherketone (PEEK) Rods.Indian journal of orthopaedics · 2026Article
- Review
- Changing rod stiffness to moderate stress of adjacent disc in oblique lumbar interbody fusion - a finite element analysis.BMC musculoskeletal disorders · 2025Article
- A Finite Element Study of Simulated Fusion in an L4-L5 Model: Influence of the Combination of Materials in the Screw-and-Rod Fixation System on Reproducing Natural Bone Behavior.Biomimetics (Basel, Switzerland) · 2025Article
- Innovative technologies in thoracolumbar and lumbar spine surgery failing to reach standard of care: state-of-art review.Spine deformity · 2024Review
- Retrieval analysis of PEEK rods pedicle screw system: three cases analysis.BMC musculoskeletal disorders · 2024Article
- Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis.BMC surgery · 2024Article
- Article
- Hybrid surgery with PEEK rods for lumbar degenerative diseases: a 2-year follow-up study.BMC musculoskeletal disorders · 2022Article
- Do PEEK Rods for Posterior Instrumented Fusion in the Lumbar Spine Reduce the Risk of Adjacent Segment Disease?International journal of spine surgery · 2021Article
- Biomechanical Investigation Between Rigid and Semirigid Posterolateral Fixation During Daily Activities: Geometrically Parametric Poroelastic Finite Element Analyses.Frontiers in bioengineering and biotechnology · 2021Article
- Three-Dimensional-Printed Polyether Ether Ketone Implants for Orthopedics.Indian journal of orthopaedicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of this systematic review is to evaluate the safety and effectiveness of polyetheretherketone (PEEK) rod systems in patients receiving lumbar interbody fusion treatment. Meta-analyses of relevant clinical data were also conducted when possible.
methodsRelevant studies were identified by searching the PubMed, EMBASE, and Cochrane Library databases. Clinical studies evaluating the safety and/or effectiveness of the PEEK rod spinal stabilization system in patients receiving lumbar spinal fusion procedure were included. Studies regarding dynamic stabilization and hybrid stabilization (fixed and dynamic; eg, topping-off technique) were not included in this analysis. The analyses included patients who had a lumbar fusion procedure with PEEK rods or titanium rods as a control reference (only for controlled studies). Fusion success, functional and pain improvement, and safety data were evaluated, if reported.
resultsThe search yielded 5 studies (1 prospective and 4 retrospectives) that included 177 participants (156 received PEEK rods, and 21 received titanium rods). Meta-analysis of interbody fusion success rate in PEEK rod patients yields the estimate of 95.6% (confidence interval: 91.6% to 98.4%). Functional outcomes in PEEK rod patients demonstrated clinically significant improvement when comparing postoperative to preoperative scores, with an average improvement of 67.4% ± 8.5%. Similarly, pain improvement was clinically significant with an average visual analog scores-back pain and visual analog scores-leg pain improvement percentages of 68.9% ± 8.6% and 76.6% ± 1.5%, respectively. Rod fracture was not reported in any of the studies. The rates of screw fracture and loosening were 3/114 (2.6%) and 1/50 (2.0%), respectively. In the controlled study, no statistically significant difference was reported in the fusion success rate, function improvement, pain improvement, or device-related events between subjects treated with PEEK rods and the subjects treated with titanium rods.
conclusionsExperience with PEEK rod systems has shown satisfactory clinical outcomes. Therefore, these results support the use of PEEK rod systems as supplemental fixation during lumbar fusion procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials