ArticleJournal of clinical medicine2018
Can Photoplethysmography Replace Arterial Blood Pressure in the Assessment of Blood Pressure?
Article in Journal of clinical medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04379986 (Remote Blood Pressure Monitoring With the Wearable SENBIOSYS Photoplethysmographic Device), which is not on this map. Cited by 44 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Remote Blood Pressure Monitoring With the Wearable SENBIOSYS Photoplethysmographic Device
Who cites it
44 citing papers in PubMed, 131 citations in OpenAlex.
- Employing machine learning techniques for non-invasive blood pressure classification using photoplethysmography signals.Physical and engineering sciences in medicine · 2026Article
- Multi-Stage BiSTU Network Combining BiLSTM and Transformer for ABP Waveform Prediction from PPG Signals.Annals of biomedical engineering · 2025Article
- Cuff-less blood pressure monitoring via PPG signals using a hybrid CNN-BiLSTM deep learning model with attention mechanism.Scientific reports · 2025Article
- Blood Pressure Difference Between Cuff Inflation and Deflation by Auscultatory Method: Impact of Hypertension Grade.Diagnostics (Basel, Switzerland) · 2025Article
- 1DCNN-BiLSTM-transformer hypertension risk prediction model based on APW.Frontiers in microbiology · 2025Article
- Robust modelling of arterial blood pressure reconstruction from photoplethysmography.Scientific reports · 2024Article
- Novel metrics for tracking blood pressure changes incontinuous cuffless blood pressure estimations.Scientific reports · 2024Article
- Obstructive sleep apnea and hypertension; critical overview.Clinical hypertension · 2024Review
- Hemodynamic Bedside Monitoring Instrument with Pressure and Optical Sensors: Validation and Modality Comparison.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
- Non-Invasive Blood Pressure Tracking of Spontaneous Hypertension Rats Using an Electronic Nose.Sensors (Basel, Switzerland) · 2023Article
- Improved Hypertension Risk Assessment with Photoplethysmographic Recordings Combining Deep Learning and Calibration.Bioengineering (Basel, Switzerland) · 2023Article
- Red Blood Cells' Area Deformation as the Origin of the Photoplethysmography Signal.Sensors (Basel, Switzerland) · 2023Article
- Article
- Nocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning.Sensors (Basel, Switzerland) · 2023Article
- PPG Signals-Based Blood-Pressure Estimation Using Grid Search in Hyperparameter Optimization of CNN-LSTM.Diagnostics (Basel, Switzerland) · 2023Article
- Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations.Scientific reports · 2023Article
- Quantification of the Phenomena Affecting Reflective Arterial Photoplethysmography.Bioengineering (Basel, Switzerland) · 2023Article
- A Multi-Site, Multi-Wavelength PPG Platform for Continuous Non-Invasive Health Monitoring in Hospital Settings.IEEE transactions on biomedical circuits and systems · 2023Article
- A benchmark for machine-learning based non-invasive blood pressure estimation using photoplethysmogram.Scientific data · 2023Article
- Upper-Arm Photoplethysmographic Sensor with One-Time Calibration for Long-Term Blood Pressure Monitoring.Biosensors · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 4 countries.
Funding
Abstract
Arterial Blood Pressure (ABP) and photoplethysmography (PPG) are both useful techniques to monitor cardiovascular status. Though ABP monitoring is more widely employed, this procedure of signal acquisition whether done invasively or non-invasively may cause inconvenience and discomfort to the patients. PPG, however, is simple, noninvasive, and can be used for continuous measurement. This paper focuses on analyzing the similarities in time and frequency domains between ABP and PPG signals for normotensive, prehypertensive and hypertensive subjects and the feasibility of the classification of subjects considering the results of the analysis performed. From a database with 120 records of ABP and PPG, each 120 s in length, the records where separated into epochs taking into account 10 heartbeats, and the following statistical measures were performed: Correlation (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.