Evidence map›Paper›PMID 30269171›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019

Motion type and knee articular conformity influenced mid-flexion stability of a single radius knee prosthesis.

Xiao-Hong Wang, Da-Yong Song, Xiang Dong, Toru Suguro, Cheng-Kung Cheng

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

Xiao-Hong WangSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Da-Yong SongBeijing Medical Implant Engineering Research Center, Beijing Naton Technology Group Co. LTD, Beijing, 100082, China.
Xiang DongBeijing Engineering Laboratory of Functional Medical Materials and Devices, Beijing Naton Technology Group Co. LTD, Beijing, 100082, China.
Toru SuguroJapan Research Institute of Artificial Joint, Research Institute of Rheumatology Medical Treatment, Tokyo, 104-0032, Japan.
Cheng-Kung ChengSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China. ckcheng2009@gmail.com.ORCID http://orcid.org/0000-0002-2167-6873
Advanced Technology & Materials (China) · CNBeijing Advanced Sciences and Innovation Center · CNChina Iron and Steel Research Institute Group · CNJapan Research Institute · JP

Funding

Chinese National Science and Technology Program (National Key Research and Development Plan) 210YBXM2016110002
6 · The paper itself

Abstract

purposeSingle radius knee implants were introduced to reduce the level of paradoxical anterior femoral translation (AFT) during mid-flexion after total knee arthroplasty. Findings from clinical and experiment studies are inconsistent, which may be due to the different loading conditions and articular conformities of the knee implants studied. The aim of this study is to analyze how variations in these two factors affect the mid-flexion stability of a single radius knee prosthesis.

methodsSix daily activities (walking, stair ascent, stair descent, sit-to-stand, pivot turn and crossover turn), and three articular conformity ratios (low, moderate and high) were considered. The resulting AFTs from the 18 finite element models were analyzed.

resultsFor low conformity knees, the worst case activity (the greatest AFT) was sit-to-stand with an AFT of 6.2 mm, while for the moderate conformity the worst case was crossover turn and pivot turn. For high conformity, all activities produced a relatively small AFT ranging from 0 mm to 1.8 mm, which more closely resembles natural knee motion. In addition, no AFT was recorded during stair ascent for all three conformities (low, moderate, high).

conclusionsThis study demonstrated that the amount of AFT is highly dependent on the activity being undertaken and the articular conformity of the knee prosthesis, and the worst case activity depends on the knee conformity. The clinical relevance of this study is that it offers valuable information towards the design of improved knee prostheses and selection of knee implants for clinical use. LEVEL OF EVIDENCE: II.

Indexed as

Arthroplasty, Replacement, KneeProsthesis DesignBiomechanical PhenomenaComputer SimulationFemurFinite Element AnalysisHumansKineticsKnee JointKnee ProsthesisRadiusRange of Motion, ArticularTibiaTorqueWalkingAnterior femoral translation (AFT)Conformity ratioDaily activityMid flexion stabilitySingle radius knee

Identifiers

PMID30269171
OpenAlexW2894010407

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.