ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2018
Photonic band-gap resonators for high-field/high-frequency EPR of microliter-volume liquid aqueous samples.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Bimodal Q-band probehead with improved signal-to-noise ratio in pulse electron paramagnetic resonance.Magnetic resonance (Gottingen, Germany) · 2026Article
- Field-domain rapid-scan EPR at 240GHz for studies of protein functional dynamics at room temperature.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024Article
- High-frequency high-power DNP/EPR spectrometer operating at 7 T magnetic field.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024Article
- Recent advances in microresonators and supporting instrumentation for electron paramagnetic resonance spectroscopy.The Review of scientific instruments · 2022Article
- Characterization of photonic band resonators for DNP NMR of thin film samples at 7 T magnetic field.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2021Article
- Increased flow rate of hyperpolarized aqueous solution for dynamic nuclear polarization-enhanced magnetic resonance imaging achieved by an open Fabry-Pérot type microwave resonator.Magnetic resonance (Gottingen, Germany) · 2020Article
- Multi-resonant photonic band-gap/saddle coil DNP probehead for static solid state NMR of microliter volume samples.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
High-field EPR provides significant advantages for studying structure and dynamics of molecular systems possessing an unpaired electronic spin. However, routine use of high-field EPR in biophysical research, especially for aqueous biological samples, is still facing substantial technical difficulties stemming from high dielectric millimeter wave (mmW) losses associated with non-resonant absorption by water and other polar molecules. The strong absorbance of mmW's by water also limits the penetration depth to just fractions of mm or even less, thus making fabrication of suitable sample containers rather challenging. Here we describe a radically new line of high Q-factor mmW resonators that are based on forming lattice defects in one-dimensional photonic band-gap (PBG) structures composed of low-loss ceramic discs of λ/4 in thickness and having alternating dielectric constants. A sample (either liquid or solid) is placed within the E = 0 node of the standing mm wave confined within the defect. A resonator prototype has been built and tested at 94.3 GHz. The resonator performance is enhanced by employing ceramic nanoporous membranes as flat sample holders of controllable thickness and tunable effective dielectric constant. The experimental Q-factor of an empty resonator was ≈ 420. The Q-factor decreased slightly to ≈ 370 when loaded with a water-containing nanoporous disc of 50 μm in thickness. The resonator has been tested with a number of liquid biological samples and demonstrated about tenfold gain in concentration sensitivity vs. a high-Q cylindrical TE
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.