ArticleiScience2018
A Membrane-Bound Biosensor Visualizes Shear Stress-Induced Inhomogeneous Alteration of Cell Membrane Tension.
Article in iScience, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed.
- Discoidin domain receptor 1 (DDR1): An emerged novel mechanosensor.Fundamental research · 2026Review
- Mechanical Signaling: Molecular Mechanisms, Biological Functions, Diseases, and Therapeutic Targets.MedComm · 2025Review
- Cellular Adaptation to Mechanical Stress Emerges via Cell Shrinkage Triggered by Nonlinear Calcium Elevation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Visualization of RIM-BP2's crane-like function in neuronal vesicle transport using FRET.Communications biology · 2025Article
- External strain on the plasma membrane is relayed to the endoplasmic reticulum by membrane contact sites and alters cellular energetics.Science advances · 2025Article
- Unravelling molecular dynamics in living cells: Fluorescent protein biosensors for cell biology.Journal of microscopy · 2025Review
- Numerical Flow Simulations of the Shear Stress Forces Arising in Filtration Slits during Glomerular Filtration in Rat Kidney.Journal of the American Society of Nephrology : JASN · 2025Article
- Analytical methods in studying cell force sensing: principles, current technologies and perspectives.Regenerative biomaterials · 2025Review
- Tutorial: fluorescence lifetime microscopy of membrane mechanosensitive Flipper probes.Nature protocols · 2024Review
- Article
- Tropomodulin1 exacerbates inflammatory response in macrophages by negatively regulating LPS-induced TLR4 endocytosis.Cellular and molecular life sciences : CMLS · 2024Article
- Cell Membrane Tension Gradients, Membrane Flows, and Cellular Processes.Physiology (Bethesda, Md.) · 2024Review
- Endothelial discoidin domain receptor 1 senses flow to modulate YAP activation.Nature communications · 2023Article
- Article
- Interplay between mechanics and signalling in regulating cell fate.Nature reviews. Molecular cell biology · 2022Review
- Emerging Piezo1 signaling in inflammation and atherosclerosis; a potential therapeutic target.International journal of biological sciences · 2022Review
- Review
- Correlated flickering of erythrocytes membrane observed with dual time resolved membrane fluctuation spectroscopy under different D-glucose concentrations.Scientific reports · 2021Article
- Visualizing the Invisible: Advanced Optical Microscopy as a Tool to Measure Biomechanical Forces.Frontiers in cell and developmental biology · 2021Review
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cell membrane is the first medium from where a cell senses and responds to external stress stimuli. Exploring the tension changes in cell membrane will help us to understand intracellular force transmission. Here, a biosensor (named MSS) based on fluorescence resonance energy transfer is developed to visualize cell membrane tension. Validity of the biosensor is first verified for the detection of cell membrane tension. Results show a shear stress-induced heterogeneous distribution of membrane tension with the biosensor, which is strengthened by the disruption of microfilaments or enhancement of membrane fluidity, but weakened by the reduction of membrane fluidity or disruption of microtubules. These findings suggest that the MSS biosensor is a beneficial tool to visualize the changes and distribution of cell membrane tension. Besides, cell membrane tension does not display obvious polar distribution, indicating that cellular polarity changes do not first occur on the cell membrane during mechanical transmission.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.