Evidence map›Paper›PMID 30267340›Full record

Trial reportJournal of anesthesia2018

Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study.

Takashi Juri, Koichi Suehiro, Aya Kimura, Akira Mukai, Katsuaki Tanaka, Tokuhiro Yamada, Takashi Mori, Kiyonobu Nishikawa

3 registry-linked trialsAbstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Journal of anesthesia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04752904 nacompletednot on this mapstarted 2021, after this paper: background citation

Noninvasive Continuous Blood Pressure Monitoring for Preventing Post-spinal Hypotension During Cesarean Delivery: A Randomized Controlled Trial

TypeinterventionalSponsorSeoul National University HospitalRan2021 to 2022Enrolled154ConditionsCesarean Section Complications, HypotensionArmsClearSight System
NCT05513066 unknown statusnot on this mapstarted 2022, after this paper: background citation

Prospective, Observational and Bicentric Study of the Management of Arterial Hypotension During Planned Caesarean Section. Practice Comparison Between a Referral Center Using According to Service Protocol, an Intravenous Ephedrine/Phenylephrine Mixture at the PSE Versus Another Referral Center Using According to Service Protocol Intravenous Baby Noradrenaline

TypeobservationalSponsorUniversity Hospital, Clermont-FerrandRan2022 to 2024Enrolled300ConditionsHypotension
NCT06729827 nacompletednot on this mapstarted 2025, after this paper: background citation

Non-invasive PREDIctive Hemodynamic Continuous moniToring vs Standard Intermittent Blood Pressure and Post-spinal hypotensION During Elective Cesarean Section: a Randomized Clinical Trial

TypeinterventionalSponsorFondazione Policlinico Universitario Agostino Gemelli IRCCSRan2025 to 2025Enrolled102ConditionsPregnancy Related, Cesarean Section Complications, Hypotension on Induction, Anesthesia ComplicationArmsHypotension prediction Index - HPI
3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 29 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Review
  7. Observational
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Reply to the letter.Journal of anesthesia · 2019
    Article
  16. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Takashi JuriDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Koichi SuehiroDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan. suehirokoichi@yahoo.co.jp.ORCID http://orcid.org/0000-0002-2156-6092
Aya KimuraDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Akira MukaiDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Katsuaki TanakaDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Tokuhiro YamadaDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Takashi MoriDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Kiyonobu NishikawaDepartment of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Osaka City University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to investigate the efficacy of the ClearSight™ system (Edwards Lifesciences, Irvine, CA) for reducing the incidence of hypotension compared with the traditional oscillometric blood pressure monitoring in cesarean delivery under spinal anesthesia.

methodsForty patients undergoing cesarean delivery under spinal anesthesia were enrolled. The patients were randomly divided into two groups (Control and ClearSight groups). All patients received spinal anesthesia using 0.5% hyperbaric bupivacaine (11.5 mg) and fentanyl (10 µg). Blood pressure was managed with the same protocol using the ClearSight™ system (ClearSight group) and oscillometric blood pressure monitoring (Control group). Furthermore, we compared the accuracy of the ClearSight™ system with the traditional oscillometric monitoring for blood pressure measurement using Bland-Altman, four-quadrant plot, and polar plot analyses.

resultsThe incidence of hypotension was significantly lower in the ClearSight group from induction to delivery (45% vs. 0%, p < 0.001) and to the end of surgery (50% vs. 20%, p = 0.049). Intraoperative nausea occurred more frequently in the Control group (45% vs. 10%, p = 0.012). The ClearSight™ system demonstrated acceptable accuracy with a bias of - 4.3 ± 11.7 mmHg throughout the procedure. Four-quadrant analysis revealed an excellent trending ability of the ClearSight™ system with a concordance rate of approximately 95%. In the polar plot analysis, the angular bias and concordance rate were - 13.5° ± 19.0° and 76.9%, respectively.

conclusionsThe accuracy and trending ability of the ClearSight™ system for blood pressure measurement was clinically acceptable in cesarean delivery under spinal anesthesia, leading to reductions in maternal hypotension and nausea.

Indexed as

AdultAnesthesia, ObstetricalAnesthesia, SpinalBlood PressureBlood Pressure DeterminationBupivacaineCesarean SectionFemaleFentanylHumansHypotensionPregnancyBupivacaineFentanylCesarean deliveryClearSight™HypotensionSpinal anesthesia

Identifiers

PMID30267340
OpenAlexW2892576871

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.