Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate.
Article in International orthopaedics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 15 citations in OpenAlex.
- Clinical outcomes and risk factors in the surgical treatment of distal femur fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Novel Implant, Novel Pattern of Failure: Potentially Occult but Implant Specific Failure of a Variable Locking Distal Femoral Plate.ANZ journal of surgery · 2025Article
- A retrospective cohort analysis of failure and potential causes after osteosynthesis of femoral fractures with VA-LCP Condylar plate 4.5/5.0, Depuy Synthes.Journal of orthopaedics · 2024Article
- A novel anatomical locked medial femoral condyle plate: a biomechanical study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
- Retrograde intramedullary nailing or locked plating for stabilisation of distal femoral fractures? A comparative study of 193 patients.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
- DISTAL FEMORAL FRACTURES FROM HIGH-ENERGY TRAUMA: A RETROSPECTIVE REVIEW OF COMPLICATION RATE AND RISK FACTORS.Acta ortopedica brasileira · 2022Article
- Clinical outcomes of revision with retrograde intermedullary nailing for failed plating of distal femoral fractures: a retrospective study.International orthopaedics · 2020Article
- Functional outcome of open distal femoral fractures managed with lateral locking plates.International orthopaedics · 2020Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeGiven the recent controversy in the literature and the alarming reports of early mechanical failure associated with the use of the Synthes 4.5 mm VA-LCP Curved Condylar Plate in acute distal femur fractures, the goal of our study was to examine the outcomes and mechanical failure rates of this implant in a larger patient population.
methodsPatients 18 years of age and older who underwent plate fixation of their acute distal femoral fracture using the Synthes 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. The study data was collected through a retrospective chart review and review of the existing radiographic studies. Primary outcome measure was mechanical hardware failure while secondary outcome measures included nonunion, malunion, and medical and surgical complications.
resultsA total of 74 patients (77 fractures) were included in this study. The fractures were classified according to the OTA/AO classification as 33-A2 (n = 6), 33-A3 (n = 19), 33-C1 (n = 5), 33-C2 (n = 25), and 33-C3 (n = 22). Thirty-two out of 77 fractures presented as open fractures (41.6%). A mechanical failure was observed in 7 patients (9.1%). Twenty additional patients needed a re-operation of the surgical site including two nonunion repairs, one malunion repair, 15 staged treatments of traumatic segmental bone defects, and two soft tissue debridements.
conclusionsIn our experience, the Synthes 4.5 mm VA-LCP Curved Condylar Plate is a safe and effective implant with a relatively low mechanical failure rate.