Evidence map›Paper›PMID 30264241›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019

The challenge of implant integration in partial meniscal replacement: an experimental study on a silk fibroin scaffold in sheep.

Svenja Emmi Catherine Stein, Falk von Luebken, Daniela Warnecke, Cristina Gentilini, Nick Skaer, Robert Walker, Oliver Kessler, Anita Ignatius, Lutz Duerselen

Open access · hybridAbstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Natural biopolymer scaffold for meniscus tissue engineering.Frontiers in bioengineering and biotechnology · 2022
    Review
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 3 countries.

Svenja Emmi Catherine SteinInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany. svenja.stein@uni-ulm.de.
Falk von LuebkenDepartment of Trauma and Orthopaedic Surgery, Hospital of the German Armed Forces Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany.
Daniela WarneckeInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.
Cristina GentiliniOrthox Ltd., 66 Innovation Drive, Milton Park, Abingdon, Oxfordshire, OX14 4RQ, UK.
Nick SkaerOrthox Ltd., 66 Innovation Drive, Milton Park, Abingdon, Oxfordshire, OX14 4RQ, UK.
Robert WalkerOrthox Ltd., 66 Innovation Drive, Milton Park, Abingdon, Oxfordshire, OX14 4RQ, UK.
Oliver KesslerCentre of Orthopaedics and Sports, Albisriederstraße 243 A, 8047, Zurich, Switzerland.
Anita IgnatiusInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.
Lutz DuerselenInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.
Helmholtz-Institute Ulm · DEOrthox (United Kingdom) · GBBundeswehrCenter for Pediatric Endocrinology Zurich · CH

Funding

German Armed Forces E/U2AD/ED001/EF551Innovate UK Regenerative Medicine Programme 102162NIHR Invention for Innovation Programme (i4i) II-LS-1010-100009
6 · The paper itself

Abstract

purposeTo restore meniscal function after excessive tissue damage, a silk fibroin implant for partial meniscal replacement was developed and investigated in an earlier sheep model. After 6 months implantation, it showed promising results in terms of chondroprotection and biocompatibility. To improve surgical fixation, the material was subjected to optimisation and a fibre mesh was integrated into the porous matrix. The aim of the study was the evaluation of this second generation of silk fibroin implants in a sheep model.

methodsNine adult merino sheep received subtotal meniscal replacement using the silk fibroin scaffold. In nine additional animals, the defect was left untreated. Sham surgery was performed in another group of nine animals. After 6 months of implantation macroscopic, biomechanical and histological evaluations of the scaffold, meniscus, and articular cartilage were conducted.

resultsMacroscopic evaluation revealed no signs of inflammation of the operated knee joint and most implants were located in the defect. However, there was no solid connection to the remaining peripheral meniscal rim and three devices showed a radial rupture at the middle zone. The equilibrium modulus of the scaffold increased after 6 months implantation time as identified by biomechanical testing (before implantation 0.6 ± 0.3 MPa; after implantation: 0.8 ± 0.3 MPa). Macroscopically and histologically visible softening and fibrillation of the articular cartilage in the meniscectomy- and implant group were confirmed biomechanically by indentation testing of the tibial cartilage.

conclusionsIn the current study, biocompatibility of the silk fibroin scaffold was reconfirmed. The initial mechanical properties of the silk fibroin implant resembled native meniscal tissue. However, stiffness of the scaffold increased considerably after implantation. This might have prevented integration of the device and chondroprotection of the underlying cartilage. Furthermore, the increased stiffness of the material is likely responsible for the partial destruction of some implants. Clinically, we learn that an inappropriate replacement device might lead to similar cartilage damage as seen after meniscectomy. Given the poor acceptance of the clinically available partial meniscal replacement devices, it can be speculated that development of a total meniscal replacement device might be the less challenging option.

Indexed as

FibroinsProstheses and ImplantsTissue ScaffoldsAnimalsBiomechanical PhenomenaMenisci, TibialModels, AnimalSheepFibroinsMeniscal replacementMeniscectomyMeniscusOsteoarthritisPermanent replacementScaffoldSilkSilk fibroin

Identifiers

PMID30264241
PMCPMC6394547
OpenAlexW2893827043

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.