Evidence map›Paper›PMID 30261203›Full record

ArticleJournal of controlled release : official journal of the Controlled Release Society2018

PLGA microsphere/PVA hydrogel coatings suppress the foreign body reaction for 6 months.

Bing Gu, Fotios Papadimitrakopoulos, Diane J Burgess

Abstract read
In one paragraph

Article in Journal of controlled release : official journal of the Controlled Release Society, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Review
  10. Biomedical Implants with Charge-Transfer Monitoring and Regulating Abilities.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Review
  11. Article
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Bing GuUniversity of Connecticut, School of Pharmacy, Storrs, CT 06269, USA.
Fotios PapadimitrakopoulosUniversity of Connecticut, School of Pharmacy, Storrs, CT 06269, USA.
Diane J BurgessUniversity of Connecticut, School of Pharmacy, Storrs, CT 06269, USA. Electronic address: d.burgess@uconn.edu.

Funding

Protein Biosensor Arrays Based on NanomaterialsR01EB014586 · NIBIB · UNIVERSITY OF CONNECTICUT STORRS · PI RUSLING, JAMES F. · 2011 to 2014
$1.4M
Needle-Implantable, Wireless Multi-Sensor for Continuous Glucose MonitoringR43EB011886 · NIBIB · BIORASIS, INC. · PI ISLAM, SYED K., JAIN, FAQUIR C · 2009 to 2010
$901k
Miniaturized Wireless Implantable Biosensors for Metabolic MonitoringR21HL090458 · NHLBI · UNIVERSITY OF CONNECTICUT STORRS · PI BURGESS, DIANE JANE · 2007 to 2009
$692k
NHLBI NIH HHS R21 HL090458NIBIB NIH HHS R01 EB014586NIBIB NIH HHS R43 EB011886
6 · The paper itself

Abstract

The application of dexamethasone releasing poly (lactic-co-glycolic acid) (PLGA) microspheres embedded in a poly vinyl alcohol (PVA) hydrogel coatings have been successfully used in the suppression of the foreign body response (FBR) to implantable glucose sensors. In the current study, dexamethasone-loaded PLGA microspheres were prepared by blending two types of PLGA polymers (RG503H and DLG7E with MW of ca. 25 kDa and 113 kDa, respectively) to achieve long-term (6 months) inhibition of the FBR. The microsphere composition was optimized according to the in vitro drug release profiles. Microspheres with DLG7E/RG503H/dexamethasone = 70/13.3/16.7 wt% composition, when embedded in a PVA hydrogel, provided a continuous drug release for 6 months. By combining the aforementioned microspheres with microspheres composed solely of the DLG7E polymer within a similar PVA hydrogel realized an even longer (>7 months) in vitro drug release. A heat map was constructed to depict the daily in vitro drug released and elucidate possible lag phases that could affect the pharmacodynamic response. These drug-loaded implant coatings were investigated in vivo (rat model) and showed inhibition of the foreign body response for 6 months. These results suggest that the minimum effective daily dose to counter chronic inflammation is ca. 0.1 μg per mg of coating surrounding a 0.5 × 0.5 × 5 mm silicon implant (dummy sensor). Accordingly, these drug-eluting composite coatings can ensure long-term inflammation control for miniaturized implantable devices.

Indexed as

AnimalsBiosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringCoated Materials, BiocompatibleDelayed-Action PreparationsDexamethasoneDrug CarriersDrug ImplantsDrug LiberationForeign-Body ReactionHydrogelsMaleMicrospheresParticle SizePolylactic Acid-Polyglycolic Acid CopolymerBlood GlucoseCoated Materials, BiocompatibleDelayed-Action PreparationsDexamethasoneDrug CarriersDrug ImplantsHydrogelsPolylactic Acid-Polyglycolic Acid CopolymerPolyvinyl AlcoholDose responseHeat mapLong-termPLGA microspherePolymer blends

Identifiers

PMID30261203
PMCPMC8184021

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.