Evidence map›Paper›PMID 30259692›Full record

ArticleJournal of biophotonics2019

Development of a visually guided Raman spectroscopy probe for cervical assessment during pregnancy.

Christine M O'Brien, Katherine J Cochran, Laura E Masson, Mack Goldberg, Eric Marple, Kelly A Bennett, Jeff Reese, James C Slaughter, J M Newton, Anita Mahadevan-Jansen

Abstract read
In one paragraph

Article in Journal of biophotonics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. In vivo Raman spectroscopy monitors cervical change during labor.American journal of obstetrics and gynecology · 2022
    Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Christine M O'BrienDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee.
Katherine J CochranDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee.
Laura E MassonDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee.
Mack GoldbergDepartment of Obstetrics and Gynecology, Vanderbilt University Medical Center, Nashville, Tennessee.
Eric MarpleEmVision LLC, Loxahatchee, Florida.
Kelly A BennettDepartment of Obstetrics and Gynecology, Vanderbilt University Medical Center, Nashville, Tennessee.
Jeff ReeseBiophotonics Center, Vanderbilt University, Nashville, Tennessee.
James C SlaughterDepartment of Biostatistics, Vanderbilt University Medical Center, Nashville, Tennessee.
J M NewtonDepartment of Obstetrics and Gynecology, Vanderbilt University Medical Center, Nashville, Tennessee.
Anita Mahadevan-JansenDepartment of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee.

Funding

The Vanderbilt Institute for Clinical and Translational Research (VICTR)UL1TR000445 · NCATS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI BERNARD, GORDON RAPHAEL · 2012 to 2016
$41.4M
Training Program for Innovative Engineering Research in Surgery and InterventionT32EB021937 · NIBIB · VANDERBILT UNIVERSITY · PI Dario J Englot, Michael Ian Miga · 2016 to 2026
$2.3M
Detecting biochemical changes in the pregnant mouse cervix by Raman spectroscopyR01HD081121 · NICHD · VANDERBILT UNIVERSITY MEDICAL CENTER · PI MAHADEVAN-JANSEN, ANITA, REESE, JOHN JEFFREY · 2014 to 2018
$1.9M
NCATS NIH HHS UL1 TR000445NIBIB NIH HHS T32 EB021937NICHD NIH HHS R01 HD081121
6 · The paper itself

Abstract

Preterm birth (PTB) is the leading cause of neonatal death, however, accurate prediction methods do not exist. Detection of early changes in the cervix, an organ that biochemically remodels to deliver the fetus, has potential to predict PTB risk. Researchers have employed light-based methods to monitor biochemical changes in the cervix during pregnancy, however, these approaches required patients to undergo a speculum examination which many patients find uncomfortable and is not standard practice during prenatal care. Herein, a visually guided optical probe is presented that measures the cervix via introduction by bimanual examination, a procedure that is commonly performed during prenatal visits and labor for tactile monitoring of the cervix. The device incorporates a Raman spectroscopy probe for biochemical monitoring and a camera for visualizing measurement location to ensure it is void of cervical mucus and blood. This probe was tested in 15 patients receiving obstetric and gynecological care, and results acquired with and without a speculum revealed similar spectra, demonstrating that the visually guided probe conserved data quality. Additionally, the majority of patients reported reduced discomfort from the device. In summary, the visual guidance probe successfully measured the cervix while integrating with standard prenatal care, reducing a barrier in clinical translation.

Indexed as

Cervix UteriEquipment DesignFemaleHumansPregnancySpectrum Analysis, Ramancervixfiber optic probeoptical diagnosispregnancyRaman spectroscopyspeculum-freevisual guidance

Identifiers

PMID30259692
PMCPMC6578580

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.