Evidence map›Paper›PMID 30259119›Full record

ArticleMikrochimica acta2018

On-off-on luminescent pyrophosphate probe based on the use of Mn-doped ZnS quantum dots and using Eu(III) as a mediator.

Jiawei Pang, Yuexiang Lu, Xinyu Gao, Panshu Song, Fengyi Yang, Yueying Liu

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiawei PangDepartment of Chemistry, Capital Normal University, Beijing, 100048, People's Republic of China.
Yuexiang LuInstitute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Beijing Key Lab of Radioactive Waste Treatment, Tsinghua University, Beijing, 100084, People's Republic of China.
Xinyu GaoDepartment of Chemistry, Capital Normal University, Beijing, 100048, People's Republic of China.
Panshu SongNational Institute of Metrology China, Beijing, 100029, People's Republic of China.
Fengyi YangDepartment of Chemistry, Capital Normal University, Beijing, 100048, People's Republic of China.
Yueying LiuDepartment of Chemistry, Capital Normal University, Beijing, 100048, People's Republic of China. yueyingliu@cnu.edu.cn.ORCID 0000-0001-5335-3334

Funding

Beijing Natural Science Foundation No. 2162010National Natural Science Foundation of China No. 21105066National Natural Science Foundation of China No.21505126National Natural Science Foundation of China No. 21775087Scientific Research Project of Beijing Educational Committee No. KM201610028008
6 · The paper itself

Abstract

A selective phosphorescent on-off-on probe with long decay lifetime has been designed for the detection of pyrophosphate ions (PPi). The detection scheme is based on the use of europium(III)-modulated Mn(II)-doped ZnS quantum dots capped with N-acetyl-L-cysteine. Both the aggregation of quantum dots and electron transfer induced by Eu(III) ions cause phosphorescence to be quenched ("off" state). Phosphorescence is, however, restored on addition of PPi to the system ("on" state). The effect is attributed to the removal of Eu(III) from the carboxy groups on the surface of the quantum dots owing to the stronger interaction between PPi and Eu(III). A linear relationship exists between phosphorescence intensity (best measured at excitation/emission wavelengths of 316/594 nm) and PPi concentration in the 400 nM to 6000 nM with a detection limit of 145 nM. An additional attractive feature is provided by the long-lived phosphorescence (1920 μs) of the quantum dots. It can be used to eliminate interference by short-lived fluorescence in biological samples by performing time resolved measurements. The probe was applied to the determination of PPi in spiked in urine samples and gave recoveries in the range from 98 to 105% with RSDs of <2.0%. Graphical abstract Schematic of a long-lived phosphorescent on-off-on probe for the sensitive and selective detection of pyrophosphate ions (PPi). It is based on the use of Eu(III)-modulated Mn(II)-doped ZnS quantum dots (QDs). Phosphorescence is quenched of QDs after the addition of Eu

Indexed as

Aggregation of QDsCoordination between Eu3+ and QDsMetal ion mediatorOn-off-on switchPhosphorescencePhosphorescence lifetimePyrophosphate detectionQuantum dots

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.