Evidence map›Paper›PMID 30257049›Full record

ArticleMagnetic resonance in medicine2019

Potential acceleration performance of a 256-channel whole-brain receive array at 7 T.

Arjan D Hendriks, Peter R Luijten, Dennis W J Klomp, Natalia Petridou

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Optical Detuning Strategies for Shielded Loop Resonators.Magnetic resonance in medicine · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. 3D FRONSAC with PSF reconstruction.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023
    Article
  6. Review
  7. A Monopole and Dipole Hybrid Antenna Array for Human Brain Imaging at 10.5 Tesla.IEEE antennas and wireless propagation letters · 2022
    Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Over-overlapped loop arrays: A numerical study.Magnetic resonance imaging · 2020
    Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Arjan D HendriksDepartment of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, Netherlands.ORCID 0000-0002-0363-2471
Peter R LuijtenDepartment of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, Netherlands.
Dennis W J KlompDepartment of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, Netherlands.
Natalia PetridouDepartment of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, Netherlands.

Funding

Netherlands Organization for Scientific Research, NWO 13339Netherlands Organization for Scientific Research, NWO ALW-834.14.004
6 · The paper itself

Abstract

purposeAssess the potential gain in acceleration performance of a 256-channel versus 32-channel receive coil array at 7 T in combination with a 2D CAIPIRINHA sequence for 3D data sets.

methodsA 256-channel receive setup was simulated by placing 2 small 16-channel high-density receive arrays at 2

resultsIn the periphery of the brain, the receive SNR was on average a factor 1.5 higher (ranging up to a factor 2.7 higher) than the 32-channel coil; in the center of the brain the SNR was comparable or lower, depending on the size of the region of interest, with a factor 1.0 on average (ranging from 0.7 up to a factor of 1.6). The average noise correlation between coil elements was 3% for the 256-channel coil, and 5% for the 32-channel coil. At acceptable g-factors (< 2), the achievable acceleration factor using SENSE and 2D CAIPIRINHA was 24 and 28, respectively, versus 9 and 12 for the 32-channel coil.

conclusionThe receive performance of the simulated 256 channel array was better than the 32-channel reference. Combined with 2D CAIPIRINHA, a peak acceleration factor of 28 was assessed, showing great potential for high-density receive arrays.

Indexed as

AlgorithmsBrainComputer SimulationHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingSignal-To-Noise Ratio256-channel receive coil2D CAIPIRINHA7 Tmassive receiveparallel imagingphased array

Identifiers

PMID30257049
PMCPMC6585755

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.