Evidence map›Paper›PMID 30255670›Full record

ArticleJournal of biomedical optics2018

Combined high-speed holographic shape and full-field displacement measurements of tympanic membrane.

Payam Razavi, Haimi Tang, John J Rosowski, Cosme Furlong, Jeffrey T Cheng

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Randomized Comparison of Endoscopic Cartilage-Perichondrium Sandwich Technique Verses Underlay Technique for Large Tympanic Membrane Perforations.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale
    Trial
  2. Article
  3. Article
  4. Contemporary Mechanics of Conductive Hearing Loss.Operative techniques in otolaryngology--head and neck surgery · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Payam RazaviWorcester Polytechnic Institute, Center for Holographic Studies and Laser micromechaTronic, Worceste, United States.
Haimi TangWorcester Polytechnic Institute, Center for Holographic Studies and Laser micromechaTronic, Worceste, United States.
John J RosowskiMassachusetts Eye and Ear Infirmary, Harvard Medical School, Eaton-Peabody Laboratory, Department of, United States.
Cosme FurlongWorcester Polytechnic Institute, Center for Holographic Studies and Laser micromechaTronic, Worceste, United States.
Jeffrey T ChengMassachusetts Eye and Ear Infirmary, Harvard Medical School, Eaton-Peabody Laboratory, Department of, United States.

Funding

Middle Ear Nonlinearity in High Intensity Sound: Impact on Hearing Damage and ProtectionR01DC016079 · NIDCD · MASSACHUSETTS EYE AND EAR INFIRMARY · PI Jeffrey Tao Cheng · 2017 to 2026
$4.1M
Computer-based Holography and Middle-Ear FunctionR01DC008642 · NIDCD · MASSACHUSETTS EYE AND EAR INFIRMARY · PI ROSOWSKI, JOHN J · 2007 to 2014
$2.2M
NIDCD NIH HHS R01 DC008642NIDCD NIH HHS R01 DC016079
6 · The paper itself

Abstract

The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics and maintaining the same coordinate system, where the TM transient displacements due to a broadband acoustic click excitation (50-μs impulse) and the shape are consecutively measured within <200  ms. Interferograms gathered with continuous high-speed (>2  kHz) optical phase sampling during a single 100-ms wavelength tuning ramp allow precise and rapid reconstructions of the TM shape at varied resolutions (50 to 200  μm). This rapid acquisition of full-field displacements and shape is immune to slow disturbances introduced by breathing or heartbeat of live subjects. Knowledge of TM shape and displacements enables the estimation of surface normal displacements regardless of the orientation of the TM within the measurement system. The proposed method helps better define TM mechanics and provides TM structure and function information useful for the diagnosis of ear disease.

Indexed as

Acoustic StimulationHolographyHumansInterferometryTympanic MembraneVibrationhigh-speed holographymiddle earshape and displacement measurementtympanic membrane

Identifiers

PMID30255670
PMCPMC6444583

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.