Evidence map›Paper›PMID 30255306›Full record

ArticleHerz2019

Transient elevation of high-sensitive troponin T after Cardioband implantation.

M M Kreusser, S T Pleger, H Abu Sharar, N A Geis, R Bekeredjian, H A Katus, P W Raake

Abstract read
PubMed Publisher
In one paragraph

Article in Herz, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

M M KreusserDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany. michael.kreusser@med.uni-heidelberg.de.
S T PlegerDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
H Abu ShararDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
N A GeisDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
R BekeredjianDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
H A KatusDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
P W RaakeDepartment of Internal Medicine III, Division of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Cardioband system enables percutaneous surgical-like direct mitral valve annuloplasty and, thereby, repair of severe functional mitral valve regurgitation (MR) in patients with advanced systolic heart failure (HF) and dilation of the left ventricular (LV) annulus. Since the device is anchored by screws in the LV annulus, limited myocardial injury is likely to occur. METHODS AND

resultsFive patients (Society of Thoracic Surgeons score: 2.7 ± 0.7%) with severe HF (LV ejection fraction [LVEF]: 17 ± 1%; LV end-diastolic diameter [LVEDD]: 71 ± 3 mm) were treated with the Cardioband (sizes C-F) receiving 14-17 screws in the LV annulus region. Myocardial injury was monitored by measuring high-sensitive cardiac troponin T (hsTnT) levels and by echocardiography. All patients showed significant periprocedural increase in hsTnT levels. Peak hsTnT concentration was reached between day 1 and day 6 (593 ± 141 pg/ml). None of the patients showed clinical signs of myocardial infarction, ST-segment elevation, new onset of deteriorated myocardial wall motion, or new ventricular tachycardia. hsTnT levels normalized in all patients after 14 days (hsTnT on day 0: 34 ± 6 pg/ml vs. hsTnT on day 14: 36 ± 6 pg/ml; p = 0.604). This nonischemic hsTnT kinetics was compared to a sixth patient who experienced proximal damage of the left circumflex artery (LCX) and ST-segment elevation during the Cardioband procedure, followed by immediate repair of the LCX, avoiding structural damage of the LV.

conclusionCardioband implantation is accompanied by significant elevation of hsTnT without causing structural myocardial damage or clinical symptoms such as worsening of LV function, new-onset LV regions exhibiting reduced wall motion, or ventricular tachycardia.

Indexed as

BiomarkersMitral Valve AnnuloplastyMitral Valve InsufficiencyTroponin TEchocardiographyHumansVentricular Function, LeftBiomarkersTroponin TCardioband deviceHeart failureHigh-sensitive cardiac troponin TMitral valve regurgitationMitral valve repair

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.