ArticleIntensive care medicine experimental2018
Bench Validation of a Compact Low-Flow CO
Article in Intensive care medicine experimental, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 18 citations in OpenAlex.
- Epoxy silane sulfobetaine block copolymers for simple, aqueous thromboresistant coating on ambulatory assist lung devices.Journal of biomedical materials research. Part A · 2024Article
- Improvement of a Mathematical Model to Predict COBioengineering (Basel, Switzerland) · 2022Article
- Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination.Membranes · 2021Article
- Suitable COBioengineering (Basel, Switzerland) · 2021Article
- A mock circulation loop to test extracorporeal COIntensive care medicine experimental · 2020Article
- In vivo testing of the low-flow COIntensive care medicine experimental · 2020Article
- In vitro characterization of PrismaLung+: a novel ECCOIntensive care medicine experimental · 2020Article
- Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs.ASAIO journal (American Society for Artificial Internal Organs : 1992)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
Abstract
backgroundThere is increasing evidence demonstrating the value of partial extracorporeal CO
methodsA blood analog was used to evaluate the performance of the pump at various impeller rotation rates. In vitro CO
resultsThe integrated pump was able to generate flows up to 700 mL/min against the Hemolung 15.5 Fr dual lumen catheter. The maximum vCO
conclusionsThe LF-PAL met pumping, CO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.