Evidence map›Paper›PMID 30251115›Full record

Trial reportJapanese journal of radiology2018

Standardization of [F-18]FDG PET/CT for response evaluation by the Radiologic Society of North America-Quantitative Imaging Biomarker Alliance (RSNA-QIBA) profile: preliminary results from the Japan-QIBA (J-QIBA) activities for Asian international multicenter phase II trial.

Hyeyeol Bae, Junichi Tsuchiya, Takehito Okamoto, Ikuko Ito, Yusuke Sonehara, Fumiko Nagahama, Kazunori Kubota, Ukihide Tateishi

Abstract readClinical Trial, Phase IIMulticenter Study
PubMed Publisher
In one paragraph

Trial report in Japanese journal of radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Trial
  2. Article
  3. Multicenter quantitativeQuantitative imaging in medicine and surgery · 2023
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hyeyeol BaeDepartment of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, Tokyo, Japan.
Junichi TsuchiyaDepartment of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, Tokyo, Japan.
Takehito OkamotoImaging Service Department, MICRON Inc, Tokyo, Japan.
Ikuko ItoImaging Service Department, MICRON Inc, Tokyo, Japan.
Yusuke SoneharaClinical Development, Solasia Pharma K.K, Tokyo, Japan.
Fumiko NagahamaAsia Clinical Development, Solasia Pharma K.K, Tokyo, Japan.
Kazunori KubotaDepartment of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, Tokyo, Japan.
Ukihide TateishiDepartment of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, Tokyo, Japan. ttisdrnm@tmd.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn an Asian international multicenter phase II trial conducted in patients with peripheral T-cell lymphoma (PTCL), [F-18]FDG-PET/CT was used for evaluation of the therapeutic response. Standardization of the PET/CT scanners was necessary before patient enrollment. We therefore standardized the scanners by phantom tests based on the profile approved by the Quantitative Imaging Biomarkers Alliance (QIBA) of Radiological Society of North America (RSNA). MATERIALS AND

methodsThe tests were conducted on 12 scanners in 12 facilities in compliance with the QIBA Profile and used National Electrical Manufacturers Association (NEMA) International Electrotechnical Commission (IEC) body phantoms. We measured three parameters (standardized uptake value [SUV], resolution and noise) and adjusted the imaging parameter values. The indexes recommended in the Japanese Society of Nuclear Medicine (JSNM) guideline were also evaluated.

resultsIn a total of 12 facilities, 6 facilities required no change in imaging conditions and 6 facilities required changes in imaging parameters. After revision, the three measurements (SUV, resolution and noise) met QIBA criteria at all sites, but 10 of the 12 scanners did not meet JSNM criteria.

conclusionWe standardized imaging conditions using phantoms as required in the RSNA-QIBA profile for response evaluation by [F-18]FDG PET/CT images in a multicenter study.

Indexed as

Fluorodeoxyglucose F18RadiopharmaceuticalsAgedArsenicalsAsiaBiomarkersFemaleGlutathioneHumansInternationalityJapanLymphoma, T-Cell, PeripheralMaleMiddle AgedNorth AmericaPhantoms, ImagingArsenicalsBiomarkersdarinaparsinFluorodeoxyglucose F18GlutathioneRadiopharmaceuticalsJ-QIBAPET/CTQIBARSNAStandardization

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.