Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients.

R Larbig, L J Motloch, M Bettin, A Fischer, N Bode, G Frommeyer, A Loeher, J Koebe, F Reinke, L Eckardt

Open access · diamondAbstract read
In one paragraph

Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Evolving use and indications for implantable cardioverter defibrillators.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

R LarbigDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany. Robert.Larbig@gmx.de.
L J MotlochDepartment of Internal Medicine II, Paracelsus Medical University, Salzburg, Austria.
M BettinDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
A FischerDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
N BodeDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
G FrommeyerDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
A LoeherDepartment of Cardiac and Thoracic Surgery, University of Muenster, Muenster, Germany.
J KoebeDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
F ReinkeDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
L EckardtDivision of Electrophysiology, Department of Cardiovascular Medicine, University of Muenster, Muenster, Germany.
University of Münster · DEParacelsus Medical University · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsTo analyse the impact of device and software updates on the prevention of T‑wave oversensing (TWOS) and inappropriate shocks (IS) in subcutaneous ICD (S-ICD) patients.

backgroundTWOS is a feared complication after implantation. It may lead to harmful IS. To date, specific strategies to reduce these events are lacking.

methodsIn this retrospective single-centre trial we analysed 146 S‑ICD patients who were implanted between 2010 and 2016. In all eligible consecutive patients (n = 139), follow-up of at least 6 weeks was studied. The incidence of TWOS/IS was analysed in patients receiving a 2

resultsBasic characteristics and indications for S‑ICD implantation were similar in both groups. However, the cumulative incidence of TWOS/IS was significantly decreased in Emblem vs. SQ (SQ: 15.4%, n = 14/91 vs. Emblem 4.2%, n = 2/48; p = 0.049). Furthermore, with regards to the SQ population we also observed a trend towards a significant reduction of TWOS/IS after installation of the software update SMR8 in 2014 (before update: 13.4%, n = 11/82 vs. after update: 4.6%, 3/65, p = 0.07).

conclusion2

Indexed as

Inappropriate shocksOversensingS-ICD

Identifiers

PMID30250998
PMCPMC6288039
OpenAlexW2892654544

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked