Evidence map›Paper›PMID 30245738›Full record

ArticleComputational and mathematical methods in medicine2018

Validity and Reliability of the Newly Developed Surface Electromyography Device for Measuring Muscle Activity during Voluntary Isometric Contraction.

Myung Hun Jang, Se Jin Ahn, Jun Woo Lee, Min-Hyung Rhee, Dasom Chae, Jinmi Kim, Myung Jun Shin

Open access · hybridAbstract readValidation Study
In one paragraph

Article in Computational and mathematical methods in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 28 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Myung Hun JangDepartment of Rehabilitation Medicine, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.ORCID 0000-0002-9694-5409
Se Jin AhnDivision of Energy and Electric Engineering, Uiduk University, Gyeongju, Republic of Korea.ORCID 0000-0002-5059-0112
Jun Woo LeeSchool of Mechanical Engineering, Pusan National University, Busan, Republic of Korea.ORCID 0000-0001-9344-1435
Min-Hyung RheeDepartment of Rehabilitation Medicine, Pusan National University Hospital, Busan, Republic of Korea.ORCID 0000-0003-4761-9364
Dasom ChaeBiomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.ORCID 0000-0003-1325-6956
Jinmi KimDepartment of Biostatistics, Clinical Trial Center, Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.ORCID 0000-0002-6715-0447
Myung Jun ShinDepartment of Rehabilitation Medicine, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.ORCID 0000-0003-4010-0383
Pusan National University Hospital · KRPusan National University · KRUiduk University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe purpose of this study was to establish the validity and reliability of the newly developed surface electromyography (sEMG) device (PSL-EMG-Tr1) compared with a conventional sEMG device (BTS-FREEEMG1000).

methodsIn total, 20 healthy participants (10 males, age 30.3 ± 2.9 years; 10 females, age 22.3 ± 2.7 years) were recruited. EMG signals were recorded simultaneously on two devices during three different isometric contractions (maximal voluntary isometric contraction (MVIC, 40% MVIC, 80% MVIC)). Two trials were performed, and the same session was repeated after 1 week. EMG amplitude recorded from the dominant biceps brachii (BB) and rectus femoris (RF) muscles was analyzed for reliability using intrasession intraclass correlation coefficient (ICC). Concurrent validity of the two devices was determined using Pearson's correlation coefficient.

resultsNonnormalized sEMG data showed moderate to very high reliability for all three contraction levels (ICC = 0.832-0.937 (BB); ICC = 0.814-0.957 (RF)). Normalized sEMG values showed no to high reliability (ICC = 0.030-0.831 (BB); ICC = 0.547-0.828 (RF)). sEMG signals recorded by the PSL-EMG-Tr1 showed good to excellent validity compared with the BTS-FREEEMG1000, at 40% MVIC (

conclusionsThe PSL-EMG-Tr1 was performed with acceptable validity. Furthermore, the high accessibility and portability of the device are useful in adjusting the type and intensity of exercise.

Indexed as

Isometric ContractionAdultElectromyographyFemaleHumansMaleMuscle ContractionMuscle, SkeletalReproducibility of ResultsRepublic of KoreaYoung Adult

Identifiers

PMID30245738
PMCPMC6136578
OpenAlexW2889179552

What OpenQuestion holds