Evidence map›Paper›PMID 30242516›Full record

ArticleInternational orthopaedics2019

Pelvic pitch and roll during total hip arthroplasty performed through a posterolateral approach. A potential source of error in free-hand cup positioning.

Alejando Gonzalez Della Valle, Kate Shanaghan, Jessica R Benson, Kaitlin Carroll, Michael Cross, Alexander McLawhorn, Peter K Sculco

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips.Therapeutics and clinical risk management · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Alejando Gonzalez Della ValleFrom the Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. gonzaleza@hss.edu.
Kate ShanaghanFrom the Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Jessica R BensonDepartment of Clinical Research, Intellijoint Surgical, Inc., Waterloo, Canada.
Kaitlin CarrollFrom the Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Michael CrossFrom the Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Alexander McLawhornFrom the Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Peter K SculcoFrom the Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Cornell University · USHospital for Special Surgery · USIntellijoint Surgical (Canada) · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIntraoperative pelvic motion can alter the perceived cup inclination and version during non-navigated THA. We quantified pelvic motion during different phases of primary THA performed in the lateral decubitus through a posterolateral approach.

methodsPelvic roll (rotation of the coronal plane) and pitch angles (rotation parallel to the coronal plane) were studied in 75 patients undergoing THA for osteoarthritis by four arthroplasty surgeons. Ten steps of surgery were defined. Angular motion was recorded with a miniature surgical device that utilizes inertial sensors.

resultsThe mean absolute roll ranged from 0.03° detected at the end of surgery to 4.13° detected during acetabular exposure. The mean absolute pitch ranged from 0.05° detected at the end of surgery to 2.54° detected during hip dislocation. The maximum pelvic roll and pitch detected during surgery averaged 17.62° (SD: 5.08) and 9.3° (SD: 3.39) respectively. Absolute roll and pitch angles were not affected by patient's BMI, sex, pre-operative hip motion, or surgeon. Before cup insertion, the greatest mean change in roll was observed during acetabular exposure (10.02° anteriorly), and for pitch was observed during dislocation (1.88° caudally).

conclusionDuring THA performed through a posterolateral approach, there is a progressive anterior pelvic roll that peaks before cup insertion. This can lead to underestimation of cup anteversion during non-navigated THA. The anterior roll does not completely correct, even when all retractors and external forces acting on the pelvis are removed. Pelvic pitch that could affect the perceived cup inclination occurs to a lesser extent than pelvic roll.

Indexed as

Hip ProsthesisAgedArthroplasty, Replacement, HipFemaleHumansIntraoperative PeriodMaleMiddle AgedMovementOsteoarthritis, HipPelvic BonesRotationSurgery, Computer-AssistedCup inclinationCup versionPelvic motionTotal hip arthroplasty

Identifiers

PMID30242516
OpenAlexW2891414411

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.