Evidence map›Paper›PMID 30240591›Full record

ArticleAnalytical biochemistry2018

Towards high-throughput fast photochemical oxidation of proteins: Quantifying exposure in high fluence microtiter plate photolysis.

Mohammad Riaz, Sandeep K Misra, Joshua S Sharp

Open access · greenAbstract read
In one paragraph

Article in Analytical biochemistry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Intrinsic Buffer Hydroxyl Radical Dosimetry Using Tris(hydroxymethyl)aminomethane.Journal of the American Society for Mass Spectrometry · 2020
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Mohammad RiazDepartment of BioMolecular Sciences, University of Mississippi, University, MS, 38677, USA.
Sandeep K MisraDepartment of BioMolecular Sciences, University of Mississippi, University, MS, 38677, USA.
Joshua S SharpDepartment of BioMolecular Sciences, University of Mississippi, University, MS, 38677, USA. Electronic address: jsharp@olemiss.edu.
University of Mississippi · US

Funding

Center of Research Excellence in Natural Products Neuroscience (CORE-NPN)P20GM104932 · NIGMS · UNIVERSITY OF MISSISSIPPI · PI MAJUMDAR, SOUMYAJIT · 2012 to 2016
$10.0M
Molecular Structure Determination by Mass Spectrometry and Computational ModelingR01GM127267 · NIGMS · UNIVERSITY OF MISSISSIPPI · PI Joshua S Sharp · 2018 to 2026
$3.8M
NIGMS NIH HHS P20 GM104932NIGMS NIH HHS R01 GM127267
6 · The paper itself

Abstract

Protein structural analysis by mass spectrometry has gained significant popularity in recent years, including high-resolution protein topographical mapping by fast photochemical oxidation of proteins (FPOP). The ability to provide protein topographical information at moderate spatial resolution makes FPOP an attractive technology for the protein pharmaceutical discovery and development processes. However, current technology limits the throughput and requires significant manual sample manipulation. Similarly, as FPOP is being used on larger samples, sample flow through the capillary becomes challenging. No systematic comparison of the performance of static flash photolysis with traditional flow FPOP has been reported. Here, we evaluate a 96-well microtiter-based laser flash photolysis method for the topographical probing of proteins, which subsequently could be used to analyze higher order structure of the protein in a high-throughput fashion with minimal manual sample manipulation. We used multiple metrics to compare microtiter FPOP performance with that of traditional flow FPOP: adenine-based hydroxyl radical dosimetry, oxidation efficiency of a model peptide, and hydroxyl radical protein footprint of myoglobin. In all cases, microtiter plate FPOP performed comparably with traditional flow FPOP, requiring a small fraction of the time for exposure. This greatly reduced sample exposure time, coupled with automated sample handling in 96-well microtiter plates, makes microtiter-based FPOP an important step in achieving the throughput required to adapt hydroxyl radical protein footprinting for screening purposes.

Indexed as

High-Throughput Screening AssaysPhotolysisCatalaseFibrinopeptide BMyoglobinOxidation-ReductionCatalaseFibrinopeptide BMyoglobinCovalent labelingFast photochemical oxidation of proteins (FPOP)Hydroxyl radical protein footprinting (HRPF)Mass spectrometryMyoglobin

Identifiers

PMID30240591
PMCPMC6186496
OpenAlexW2890155297

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.