Evidence map›Paper›PMID 30238192›Full record

ArticleJournal of the American Society for Mass Spectrometry2018

Electrospray Generated from the Tip-Sealed Fine Glass Capillary Inserted with an Acupuncture Needle Electrode.

Dilshadbek T Usmanov, Satoshi Ninomiya, Kenzo Hiraoka, Hiroshi Wada, Hiroshi Nakano, Masaya Matsumura, Sachiyo Sanada-Morimura, Hiroshi Nonami

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Dilshadbek T UsmanovClean Energy Research Center, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi, 400-8511, Japan.
Satoshi NinomiyaGraduate School, Department of Interdisciplinary Research, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi, 400-8511, Japan.
Kenzo HiraokaClean Energy Research Center, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi, 400-8511, Japan. hiraoka@yamanashi.ac.jp.
Hiroshi WadaKyushu Okinawa Agricultural Research Center, National Agriculture and Food Research Organization, 496 Izumi, Chikugo, Fukuoka, 833-0041, Japan.
Hiroshi NakanoKyushu Okinawa Agricultural Research Center, National Agriculture and Food Research Organization, 496 Izumi, Chikugo, Fukuoka, 833-0041, Japan.
Masaya MatsumuraKyushu Okinawa Agricultural Research Center, National Agriculture and Food Research Organization, Suya 2421, Goshi, Kumamoto, 861-1192, Japan.
Sachiyo Sanada-MorimuraKyushu Okinawa Agricultural Research Center, National Agriculture and Food Research Organization, Suya 2421, Goshi, Kumamoto, 861-1192, Japan.
Hiroshi NonamiPlant Biophysics/Biochemistry Research Laboratory, Faculty of Agriculture, Ehime University, Matsuyama, 790-8566, Japan.
Kyushu Okinawa Agricultural Research Center · JPUniversity of Yamanashi · JPEhime University · JPNational Agriculture and Food Research Organization · JPTakeda (Japan) · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In electrospray, excess charges are supplied to a sample solution by the occurrence of electrochemical reactions. Recently, different versions of electrospray, e.g., dielectric barrier electrospray ionization, inductive desorption electrospray ionization, and electrostatic-ionization driven by dielectric polarization, have been reported in which the sample solution was not in direct contact with the metal electrode but separated by dielectric materials. The objective of the current work is to elucidate the mechanism of dielectric barrier electrospray. A sealed borosilicate glass capillary inserted with a fine acupuncture needle was used as a probe. A sample solution (~ 400 nL) was captured on the glass capillary tip and a positive high voltage (HV) pulse (+ 4.5 kV) was applied to the internal metal electrode. Mass spectra were measured as a function of the HV pulse width from μs to 10 s. Ions started to be detected with the pulse width of ~ 5 ms. The ion intensities increased slowly with time and reached a plateau in a few seconds. The charge distribution of cytochrome c [M + nH]

Indexed as

ElectrodesNeedlesAcupuncture TherapyCytochromes cGlassSpectrometry, Mass, Electrospray IonizationCytochromes cGlass-PESIInductive electrosprayProbe electrospray ionization (PESI)Sequential electrospray

Identifiers

PMID30238192
OpenAlexW2891913760

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.