Evidence map›Paper›PMID 30238157›Full record

ArticleSurgical endoscopy2019

Tumor localization using radio-frequency identification clip marker: experimental results of an ex vivo porcine model.

Hwan Yi Joo, Bong Eun Lee, Chang In Choi, Dae Hwan Kim, Gwang Ha Kim, Tae Yong Jeon, Dong Heon Kim, Seokyoung Ahn

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hwan Yi JooSchool of Mechanical Engineering, Pusan National University, 63 BusanDaehak-Ro, GeumJeong-Gu, Busan, 46241, South Korea.
Bong Eun LeeDepartment of Gastroenterology, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea.
Chang In ChoiDepartment of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea. getz0622@naver.com.
Dae Hwan KimDepartment of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea.
Gwang Ha KimDepartment of Gastroenterology, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea.
Tae Yong JeonDepartment of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea.
Dong Heon KimDepartment of Surgery, Medical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro, Seo-Gu, Busan, 602-739, South Korea.
Seokyoung AhnSchool of Mechanical Engineering, Pusan National University, 63 BusanDaehak-Ro, GeumJeong-Gu, Busan, 46241, South Korea. sahn@pusan.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWith the widespread use of minimally invasive surgery, tumor detection is becoming more difficult. We present the experimental results of a radio-frequency identification (RFID) lesion detection system in an ex vivo porcine model.

methodsThe efficacy and feasibility of a newly developed RFID lesion detection system were examined. It was applied to the stomach and colon of pigs weighing 40 kg. The RFID clip was attached to the upper and lower mucosal sides of the stomach. Colon specimens with thin and thick walls were used. The clipped sites were marked on the serosa by a pin. The longest distance from the pin the RFID tag could be detected was measured 25 times in each direction.

resultsIn the upper gastric wall, the RFID tag detection distance was 4.5 ± 0.9 mm, 5.6 ± 0.7 mm, 12.5 ± 0.7 mm, and 5.3 ± 0.5 mm in the four directions, respectively (right, left, upper, and lower). In the antrum, the RFID tag detection distance was 5.8 ± 0.7 mm, 6.9 ± 0.5 mm, 5.6 ± 0.5 mm, and 3.7 ± 0.5 mm in the four directions. In the thin colon, the RFID tag detection distance was 6.3 ± 0.5 mm, 5.0 ± 0.5 mm, 9.7 ± 0.7 mm, and 6.4 ± 0.4 mm in the four directions. In the thick colon, the RFID tag detection distance was 3.5 ± 0.8 mm, 6.6 ± 0.5 mm, 8.4 ± 0.6 mm, and 9.8 ± 0.5 mm in the four directions. The area of detection was smallest for the antrum (83.7 mm

conclusionsThe distance at which the RFID tag was detected was usually within 10 mm. These results indicate the feasibility of the clinical application of the add-on clip and RFID tag as a marker for identifying the location of various gastrointestinal tumors.

Indexed as

AnimalsDisease Models, AnimalFeasibility StudiesMinimally Invasive Surgical ProceduresNeoplasmsRadio Frequency Identification DeviceSurgical InstrumentsSwineEndoscopic clipGastrointestinal tumorLesion detectionRadio-frequency identification

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.