Evidence map›Paper›PMID 30234896›Full record

ArticleCardiology journal2020

Reproducibility of quantitative flow ratio: An inter-core laboratory variability study.

Yunxiao Chang, Liwei Chen, Jelmer Westra, Zhongwei Sun, Changdong Guan, Yimin Zhang, Daixin Ding, Bo Xu, Shengxian Tu

Abstract readComparative StudyMulticenter Study
In one paragraph

Article in Cardiology journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Reproducibility of quantitative flow ratio: the QREP study.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2022
    Article
  7. Article
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yunxiao ChangBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Liwei ChenDepartment of Cardiology, Shin Kong Memorial Wu Ho-Su Hospital, Taipei, Taiwan.
Jelmer WestraDepartment of Cardiology, Aarhus University Hospital, Skejby, Denmark.
Zhongwei SunFu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China.
Changdong GuanFu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China.
Yimin ZhangBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Daixin DingBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Bo XuFu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China.
Shengxian TuBiomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. sxtu@sjtu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundQuantitative flow ratio (QFR) is a novel approach to derive fractional flow reserve (FFR) from coronary angiography. This study sought to evaluate the reproducibility of QFR when analyzed in independent core laboratories.

methodsAll interrogated vessels in the FAVOR II China Study were separately analyzed using the AngioPlus system (Pulse medical imaging technology, Shanghai) by two independent core laboratories, following the same standard operation procedures. The analysts were blinded to the FFR values and online QFR values. For each interrogated vessel, two identical angiographic image runs were used by two core laboratories for QFR computation. In both core laboratories QFR was successfully obtained in 330 of 332 vessels, in which FFR was available in 328 vessels. Thus, 328 vessels ended in the present statistical analysis.

resultsThe mean difference in contrast-flow QFR between the two core laboratories was 0.004 ± 0.03 (p = 0.040), which was slightly smaller than that between the online analysis and the two core laboratories (0.01 ± 0.05, p < 0.001 and 0.01 ± 0.05, p = 0.038). The mean difference of QFR with re-spect to FFR were comparable between the two core laboratories (0.002 ± 0.06, p = 0.609, and 0.002 ± 0.06, p = 0.531). Receiver operating characteristic curve analysis showed that diagnostic accuracies of QFR analyzed by the two core laboratories were both excellent (area under the curve: 0.970 vs. 0.963, p = 0.142), when using FFR as the reference standard.

conclusionsThe present study showed good inter-core laboratory reproducibility of QFR in assessing functionally-significant stenosis. It suggests that QFR analyses can be carried out in different core labo-ratories if, and only if, highly standardized conditions are maintained.

Indexed as

Coronary AngiographyFractional Flow Reserve, MyocardialChinaCoronary Artery DiseaseCoronary StenosisCoronary VesselsHumansObserver VariationPredictive Value of TestsProspective StudiesReproducibility of Resultscore laboratoriescoronary stenosisfractional flow reservequantitative flow ratioreproducibility

Identifiers

PMID30234896
PMCPMC8015972

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.