Evidence map›Paper›PMID 30228775›Full record

ArticleJournal of orthopaedics2018

Electromagnetic simulation for diagnosing damage to femoral neck vasculature: A feasibility study.

James Rizkalla, Matthew Jeffers, Paul Salama, Maher Rizkalla

Erratum issuedAbstract read
In one paragraph

Article in Journal of orthopaedics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 2 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

James RizkallaBaylor University Medical Center, Dallas, TX, United States.
Matthew JeffersDepartment of Electrical and Computer Engineering, Indiana University Purdue University Indianapolis (IUPUI), 723 West Michigan Street, Indianapolis, Inn, 46202, United States.
Paul SalamaDepartment of Electrical and Computer Engineering, Indiana University Purdue University Indianapolis (IUPUI), 723 West Michigan Street, Indianapolis, Inn, 46202, United States.
Maher RizkallaDepartment of Electrical and Computer Engineering, Indiana University Purdue University Indianapolis (IUPUI), 723 West Michigan Street, Indianapolis, Inn, 46202, United States.
Indiana University – Purdue University Indianapolis · USBaylor University Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFemoral neck fractures are common injuries managed by orthopedic surgeons across the world. From pediatrics to geriatrics, disruption of the blood supply to the femoral neck is a well-recognized source of morbidity and mortality, oftentimes resulting in avascular necrosis of the femoral head. This devastating complication occurs in 10-45% of femoral neck fractures. Therefore, it is vital for orthopedic surgeons provide efficient treatment of this injury, in order to optimize the patient's potential outcome and prevent long-term sequelae.

methodsIn this study, the anatomy of the proximal femur, including femoral metaphysis, femoral neck, vasculature, and femoral head, were simulated in COMSOL Finite Element Analysis (FEA) software. Electric fields were generated in a fashion that exploited disruptions within the vasculature of the femoral neck. This study was aimed at developing an alternative imaging modality for narrowing or disrupting the femoral neck's vasculature. The variables used for investigation included: frequency, penetration depth, and magnitude of the electrical energy. These variables, when combined, allowed for enhanced simulated visualization of the vasculature of the femoral neck and theoretically expedited diagnosis of obvious, or occult, femoral neck injury.

resultsSimulated blood vessels were developed in two-dimensions: the phi direction (circular), and z-direction. Two different frequencies, 3 GHz, and 5 GHz were considered, with 100-J energy pulses within blood vessels of 2.54 mm in diameter. The fat surrounding the bone to the outside surface body was simulated at 0.25 inch (0.65 cm). An additional model, with layered fat and skin above the vessels, was simulated at 2000J and successfully able to visualize the femoral neck's blood vessels. Results showed a distinguished E field across the blood boundary of nearly 170 V/M.

conclusionsThe electric field simulation data within the Phi and Z directions promises the feasibility of a subsequent practical model.

Identifiers

PMID30228775
PMCPMC6140380
OpenAlexW2892193172

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.