Evidence map›Paper›PMID 30225274›Full record

ArticleEuropean journal of radiology open2018

Feasibility of aortic valve planimetry at 7 T ultrahigh field MRI: Comparison to aortic valve MRI at 3 T and 1.5 T.

Juliane Goebel, Felix Nensa, Haemi P Schemuth, Stefan Maderwald, Thomas Schlosser, Stephan Orzada, Stefan Rietsch, Harald H Quick, Kai Nassenstein

Open access · goldAbstract read
In one paragraph

Article in European journal of radiology open, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Juliane GoebelDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Felix NensaDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Haemi P SchemuthDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Stefan MaderwaldErwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany.
Thomas SchlosserDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Stephan OrzadaErwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany.
Stefan RietschErwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany.
Harald H QuickErwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany.
Kai NassensteinDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Essen University Hospital · DEErwin L. Hahn Institute for Magnetic Resonance Imaging · DEUniversity of Duisburg-Essen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study examined the feasibility of aortic valve planimetry at 7 T ultrahigh field MRI in intraindividual comparison to 3 T and 1.5 T MRI. MATERIAL AND

methodsAortic valves of eleven healthy volunteers (mean age, 26.4 years) were examined on a 7 T, 3 T, and 1.5 T MR system using FLASH and TrueFISP sequences. Two experienced radiologists evaluated overall image quality, the presence of artefacts, tissue contrast ratios, identifiability, and image details of the aortic valve opening area (AVOA). Furthermore, AVOA was quantified twice by reader 1 and once by reader 2. Correlation analysis between artefact severity and employed magnetic field strength was performed by modified Fisher's exac

resultsAortic valve imaging at 7 T, 3 T, and 1.5 T with using FLASH was less hampered by artefacts than TrueFISP imaging at 3 T and 1.5 T. Tissue contrast and image details were rated best at 7 T. AVOA was measured slightly smaller at 7 T compared to 3 T (TrueFISP, p-value = 0.057; FLASH, p-value = 0.016) and 1.5 T (TrueFISP, p-value = 0.029; FLASH, p-value = 0.018). Intra-rater and inter-rater variability of AVOA tended to be slightly smaller at 7 T than at 3 T and 1.5 T.

conclusionAortic valve planimetry at 7 T ultrahigh field MRI is technically feasible and in healthy volunteers offers an improved tissue contrast and a slightly better reproducibility than MR planimetry at 1.5 T and 3 T.

Indexed as

7 T ultrahigh field MRIAortic valve imagingAortic valve opening areaCardiovascular magnetic resonance imagingPlanimetrySAR, specific absorption rateUHF, ultrahigh field

Identifiers

PMID30225274
PMCPMC6138940
OpenAlexW2892120035

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked