Evidence map›Paper›PMID 30221010›Full record

ArticleBiomedical physics & engineering express2018

Improving Edge Crystal Identification in Flood Histograms Using Triangular Shape Crystals.

Peng Peng, Chih-Chieh Liu, Junwei Du, Xiaowei Bai, Simon R Cherry

Open access · greenAbstract read
In one paragraph

Article in Biomedical physics & engineering express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. PET Detectors Based on Multi-Resolution SiPM Arrays.IEEE transactions on radiation and plasma medical sciences · 2024
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Peng PengDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.ORCID 0000-0002-3963-6482
Chih-Chieh LiuDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Junwei DuDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Xiaowei BaiDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Simon R CherryDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
University of California, Davis · US

Funding

Innovative Silicon Photomultiplier Technologies for Small-Animal PETR01EB019439 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R · 2015 to 2018
$1.4M
NIBIB NIH HHS R01 EB019439
6 · The paper itself

Abstract

This work presents a method to improve the separation of edge crystals in PET block detectors. As an alternative to square-shaped crystal arrays, we used an array of triangular-shaped crystals. This increases the distance between the crystal centres at the detector edges potentially improving the separation of edge crystals. To test this design, we have compared the flood histograms of two 4×4 scintillator arrays in both square and triangular configurations. The quality of the flood histogram was quantified using the fraction of events positioned in the correct crystal based on a 2D Gaussian fit of the segmented flood histograms. In the first study, the two crystal arrays were coupled with the SiPM directly using optical grease, and the flood histogram quality for the edge and corner crystals in the triangular-shaped array were much better than that for those crystals in the square-shaped array. The average light collection efficiency for the triangular-shaped array was 5.9% higher than that for the square-shaped array. The average energy resolution for the triangular and square shape array were 11.6% and 13.2% respectively. In the second study, two light guides with thickness 1 mm and 2 mm were used between the crystal arrays and the SiPM. The thicker lightguide degraded the light collection efficiency and energy resolution due to the light loss introduced by the light guide. However, in the 2-mm thick lightguide case, the flood histogram quality for the edge and corner crystals in the square-shaped array were improved due to better separation of those crystals in the flood histogram. Comparing the performance of the two crystal arrays with three different light guides, the triangular-shaped crystal array with no lightguide gave the best performance.

Indexed as

Detector positioningFlood histogramPET

Identifiers

PMID30221010
PMCPMC6136832
OpenAlexW2794415164

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.