Evidence map›Paper›PMID 30217094›Full record

ArticleSensors (Basel, Switzerland)2018

Design and Implementation of an Infrared Radiant Source for Humidity Testing.

Hong Zhang, Chuansheng Wang, Xiaorui Li, Boyan Sun, Dong Jiang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hong ZhangSchool of Computer Science and Technology, Harbin University of Science and Technology, 52 Xuefu Road, Harbin 150080, China. zhangh@hrbust.edu.cn.
Chuansheng WangSchool of Computer Science and Technology, Harbin University of Science and Technology, 52 Xuefu Road, Harbin 150080, China. wangchuansheng994@163.com.
Xiaorui LiSchool of Computer Science and Technology, Harbin University of Science and Technology, 52 Xuefu Road, Harbin 150080, China. 13682088813@163.com.
Boyan SunSchool of Computer Science and Technology, Harbin University of Science and Technology, 52 Xuefu Road, Harbin 150080, China. 15754509280@163.com.
Dong JiangSchool of Computer Science and Technology, Harbin University of Science and Technology, 52 Xuefu Road, Harbin 150080, China. wdyu2004@163.com.

Funding

NSFC 51377037
6 · The paper itself

Abstract

A novel way to measure humidity through testing the emissivity of an area radiant source is presented in this paper. The method can be applied in the environment at near room temperature (5~95 °C) across the relative humidity (RH) range of 20~90% RH. The source, with a grooved radiant surface, works in the far infrared wavelength band of 8~12 μm. The Monte-Carlo model for thermal radiation was set up to analyze the V-grooved radiant surface. Heat pipe technology is used to maintain an isothermal radiant surface. The fuzzy-PID control method was adopted to solve the problems of intense heat inertia and being easily interfered by the environment. This enabled the system to be used robustly across a large temperature range with high precision. The experimental results tested with a scanning radiant thermometer showed that the radiant source can provide a uniform thermal radiation capable of satisfying the requirements of humidity testing. The calibration method for the radiant source for humidity was explored, which is available for testing humidity.

Indexed as

calibrationemissivityhumidityinfrared radiant sourceMonte Carlo method

Identifiers

PMID30217094
PMCPMC6165430

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.