Evidence map›Paper›PMID 30215183›Full record

ArticleLasers in medical science2019

Temperature and depth evaluation of the in vitro effects of femtosecond laser on oral soft tissue, with or without air-cooling.

Wenjun Li, Jianqiao Zheng, Yaopeng Zhang, Fusong Yuan, Peijun Lyu

Abstract read
PubMed Publisher
In one paragraph

Article in Lasers in medical science, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Wenjun LiCenter of Digital Dentistry, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Haidian District, Beijing, 100081, People's Republic of China.
Jianqiao ZhengCenter of Digital Dentistry, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Haidian District, Beijing, 100081, People's Republic of China.
Yaopeng ZhangCenter of Digital Dentistry, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Haidian District, Beijing, 100081, People's Republic of China.
Fusong YuanCenter of Digital Dentistry, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Haidian District, Beijing, 100081, People's Republic of China. yuanfusong@bjmu.edu.cn.
Peijun LyuCenter of Digital Dentistry, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Haidian District, Beijing, 100081, People's Republic of China. kqlpj@bjmu.edu.cn.
Peking University · CN

Funding

Clinical Medicine Plus X-Young Scholars Project of Peking University PKU2018LCXQ007National Natural Science Foundation of China 81571023
6 · The paper itself

Abstract

Femtosecond laser is an effective and safe tool in many surgeries, but the studies of its effect on oral soft tissue ablation are insufficient. This study aimed to investigate the effect of soft tissue ablation with a 1030-nm femtosecond laser on temperature and depth. Twenty Sprague-Dawley rat tongue specimens were obtained and flat-mounted. The 1030-nm femtosecond laser was controlled by a computer system, with a set distance of 4.7 mm between the laser aperture and soft tissue surfaces. Ten specimens were ablated for > 1 min with or without air-cooling for temperature measurement, while the other 10 specimens were ablated for depth measurements, using the following parameters: (i) 3 W, 2000 mm/s; (ii) 3 W, 4000 mm/s; (iii) 5 W, 2000 mm/s; (iv) 5 W, 4000 mm/s; (v) 8 W, 2000 mm/s; (vi) 8 W, 4000 mm/s. Temperature changes were measured using a type-K thermocouple. The depth attained using different power and scanning speed settings was measured by a three-dimensional morphology measurement laser microscope. Laser power, scanning speed, and air-cooling effects were determined. Higher energy and lower speed induced higher temperatures (p < 0.05), which were significantly decreased by air-cooling (p < 0.05). The lowest ablation depth was obtained at 3 W and 4000 mm/s (72.63 ± 6.47 μm) (p < 0.05). The greatest incision depth was achieved at 8 W and 2000 mm/s (696.19 ± 35.37 μm), or 4000 mm/s (681.16 ± 55.65 μm) (p < 0.05). The 1030-nm femtosecond laser application demonstrates clinically acceptable ablation efficiency, without marked temperature damage, in a controlled manner.

Indexed as

Cold TemperatureLasersTemperatureAnimalsHot TemperatureMaleRats, Sprague-DawleyTime FactorsTongueAblation efficiencyFemtosecond laserSoft tissueThermal effect

Identifiers

PMID30215183
OpenAlexW2891082790

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.