Monitoring and Assessing the Degradation Rate of Magnesium-Based Artificial Bone In Vitro Using a Wireless Magnetoelastic Sensor.

Limin Ren, Kun Yu, Yisong Tan

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Electromagnetic Medical Sensing.Sensors (Basel, Switzerland) · 2019
    Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Limin RenSchool of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China. renlimin@neepu.edu.cn.ORCID 0000-0002-0200-9637
Kun YuSchool of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China. 2201700350@neepu.edu.cn.ORCID 0000-0003-4740-067X
Yisong TanSchool of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China. tanyisong@neepu.com.cn.ORCID 0000-0001-7754-6739

Funding

Key Projects of Science and Technology Development Plan of Jilin Province 20150101030JCNational Natural Science Foundation of China 51405074State Key Laboratory of Robotics and System (Harbin Institute of Technology) SKLRS-2012-MS-02
6 · The paper itself

Abstract

A magnetoelastic-based (MB) sensor was employed as a novel method to monitor and assess the degradation rate of magnesium-based artificial bone (MBAB) in vitro, which can be used as an implant to repair a bone defect, providing a quantitative method to depict the degradation rate of MBAB. MBABs were fabricated by the Pro/Engineering software and a precision machine tool using high-purity (HP) magnesium. The MB sensor was embedded in the neutral surface of MBAB by an unharmful quick adhesive, forming the MB sensor-embedded MBAB (EMBAB). The modified simulated body fluid (MSBF) media (PH = 7.4), mimicking the human internal environment, and the NaOH media (PH = 12), accelerating EMBAB's degradation, were used to immerse the EMBAB for 15 days at 37 °C. The EMBAB was then tested daily on a self-developed experimental platform to monitor the relative output power under a 100 N external force. The results showed that the relative output power of the sensing coil gradually increased with the EMBAB's degradation. The degradation rate of the EMBAB could be calculated on the basis of the changes of the relative output power caused by the MB sensor and of the degradation time. With the EMBAB's degradation, an increasing strain directly worked on the MB sensor, significantly changing the value of the relative output power, which means that the EMBAB was characterized by a quick degradation rate. During the 15 days of the experiment, the degradation rates on the 7th and 15th days were 0.005 dbm/day and 0.02 dbm/day, and 0.02 dbm/day and 0.04 dbm/day in MSBF and alkaline media, respectively. Therefore, the MB sensor provides a wireless and passive method to monitor and assess the degradation rate of bone implants in vitro.

Indexed as

Artificial OrgansBone and BonesMagneticsProstheses and ImplantsAdhesivesBody FluidsElasticityHumansIn Vitro TechniquesMagnesiumMaterials TestingWireless TechnologyAdhesivesMagnesiumdegradation ratemagnesium-based artificial bonemagnetoelastic sensorwireless and passive

Identifiers

PMID30213118
PMCPMC6165446

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.