Evidence map›Paper›PMID 30212567›Full record

ArticlePloS one2018

320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection.

Daddy Mata-Mbemba, Aissam Labani, Soraya El Ghannudi, Mi-Young Jeung, Patrick Ohlmann, Catherine Roy, Mickaël Ohana

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.9field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Daddy Mata-MbembaDepartment of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario, Canada.ORCID 0000-0002-0031-6473
Aissam LabaniDepartment of Diagnostic Imaging, Nouvel Hôpital Civil-Strasbourg University Hospital, Strasbourg, France.
Soraya El GhannudiDepartment of Diagnostic Imaging, Nouvel Hôpital Civil-Strasbourg University Hospital, Strasbourg, France.
Mi-Young JeungDepartment of Diagnostic Imaging, Nouvel Hôpital Civil-Strasbourg University Hospital, Strasbourg, France.
Patrick OhlmannDepartment of Cardiology, Nouvel Hôpital Civil-Strasbourg University Hospital, Strasbourg, France.
Catherine RoyDepartment of Diagnostic Imaging, Nouvel Hôpital Civil-Strasbourg University Hospital, Strasbourg, France.
Mickaël OhanaDepartment of Diagnostic Imaging, Nouvel Hôpital Civil-Strasbourg University Hospital, Strasbourg, France.ORCID 0000-0003-0179-5784
Hôpitaux Universitaires de Strasbourg · FRHospital for Sick Children · CALaboratoire des Sciences de l'Ingénieur, de l'Informatique et de l'Imagerie · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo reduce the iodine load required for CT Transcatheter Aortic Valve Replacement (TAVR) planning on a 320-row scanner by acquiring the two CT TAVR steps (ECG-gated aortic root CTA and non-gated aorto-ilio-femoral CTA) within a single contrast media bolus injection.

methods50 consecutive patients (82.6±6.9 years; 56% female) were prospectively enrolled and underwent a TAVR planning using a 320-row CT, with ECG-gated aortic root CTA immediately followed by a non-gated aorto-iliac acquisition, all within a single bolus of 40-70mL of Iohexol 350mgI/mL. The Iodine load, image quality, SNR, CNR and radiation dose were compared using a Mann-Whitney test to that of 24 consecutive patients (84.3±4.8 years, 58% female) previously imaged on a 64-row scanner with a conventional two-step protocol.

resultsIodine load was reduced by 44%. All examinations were of diagnostic quality, with improvement of the aortic root CTA image quality (4.9±0.3 versus 4.6±0.5, p<0.01) and a non-significant decrease of the aorto-iliac CTA image quality (4.7±0.6 versus 4.9±0.3, p = 0.07). SNR and CNR were significantly improved in the aortic root CTA (14.0±5.3 and 10.4±4.5 versus 10.3±4.2 and 6.8±3.3, p<0.01 for both) and non-significantly higher in the aorto-iliac CTA (16.5±8.0 and 14.1±7.9 versus 14.7±5.5 and 12.5±5.0, p = 0.42 and p = 0.66). Total radiation dose was reduced by 32%.

conclusion320-row CT scanner enables a 44% reduction of iodine load in TAVR planning, while maintaining excellent aorto-ilio-femoral arterial enhancement and lowering radiation dose.

Indexed as

AgedAged, 80 and overAortaAortic ValveAortic Valve StenosisComputed Tomography AngiographyContrast MediaElectrocardiographyFemaleHeart Valve ProsthesisHumansIliac ArteryInjections, IntravenousIodineIohexolMaleContrast MediaIodineIohexol

Identifiers

PMID30212567
PMCPMC6136810
OpenAlexW2890927244

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked