Evidence map›Paper›PMID 30212525›Full record

ArticlePloS one2018

Performance and usability evaluation of the INSTI HIV self-test in Kenya for qualitative detection of antibodies to HIV.

Priska Bwana, Lydia Ochieng', Matilu Mwau

Abstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Priska BwanaKenya Medical Research Institute, Busia, Kenya.ORCID 0000-0002-7368-5982
Lydia Ochieng'Kenya Medical Research Institute, Busia, Kenya.
Matilu MwauKenya Medical Research Institute, Busia, Kenya.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHIV testing is often undermined by lack of confidentiality, stigma, shortage of counselors and long distances to testing centers. Self-testing has the potential to circumvent these constraints.

objectiveTo determine the performance and usability characteristics of the INSTI® HIV-1/HIV-2 Self-Test.

methodsThe performance evaluation was a cross sectional study and the usability a mixed methods study. For method comparison, Bioelisa HIV-1+2 Ag/Ab test was used as the reference test. When the test results were discrepant, results from Alere Determine™ HIV-1/2 and First Response HIV-1-2 Antibody tests were used for confirmation of status.

resultsSensitivity of the INSTI HIV Self-Test was 98.99% (95% CI 96.05-99.75%), and specificity 98.15% (95% CI 95.63-99.23%). The concordance was therefore 97.27%. A total of 354 participants took part in the usability study. Of those, 343 (98.00%) found instructions for use easy to follow, 330 (94.29%) found the finger prick device easy to use, 303 (86.57%) were confident while performing the test, 342 (97.71%) felt result interpretation was easy, while 304 (86.86%) declared results within the recommended five minutes. Three hundred and forty two (342, 97.71%) were willing to use the test again while 344 (98.29%) would recommend the kit to a sexual partner. None of the 350 participants quit the process at any stage. Three hundred and eighteen (318, 91.12%) participants felt the test needed no further improvement. All 91 lay users correctly identified cartridges that showed positive, negative and invalid results. Only 31 (34.07%) participants correctly identified weak positive dummy test results.

conclusionThe excellent performance and usability characteristics of INSTI HIV-1/HIV-2 self-test make the kit a viable option for HIV self-testing. To improve the identification of weak positive results, the manufacturer should indicate on the IFU that even a faint test spot should be interpreted as positive.

Indexed as

AIDS SerodiagnosisCross-Sectional StudiesDiagnostic Tests, RoutineFemaleHIV-1HIV AntibodiesHIV InfectionsHumansKenyaMaleMass ScreeningPatient Acceptance of Health CareReagent Kits, DiagnosticSelf CareSensitivity and SpecificityHIV AntibodiesReagent Kits, Diagnostic

Identifiers

PMID30212525
PMCPMC6136890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.