ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2020
Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.
Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Effect of Marker Ball Positioning on Templating Accuracy in Hip Arthroplasty: A Closed-Loop Audit.Cureus · 2026Article
- Development and Validation of Radiographic Measurement Templates for Standardized X-ray Analysis.Cureus · 2025Article
- Reliably calibrating X-ray images required for preoperative planning of THA using a device-adapted magnification factor.PloS one · 2024Article
- Article
- Dual-scale single marker calibration for digital templating of total hip arthroplasty in standing radiographs: a prospective clinical study.Archives of orthopaedic and trauma surgery · 2023Observational
- Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?Journal of clinical orthopaedics and trauma · 2022Article
- Implications of component size and calibration error on digital templating for total hip arthroplasty. A visual matrix from a simple mathematical model.International journal of computer assisted radiology and surgery · 2021Article
- How Accurate is the Use of Contralateral Implant Size as a Template in Bilateral Hemiarthroplasty?Indian journal of orthopaedics · 2020Article
- A novel calibration method for digital templating of total hip arthroplasty: a prospective clinical study of dual scale type single marker calibration in supine radiographs.International orthopaedics · 2020Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThis study aims to assess the accuracy of digital templating for hip hemiarthroplasty using radiographs without calibration.
methodsTwo independent, blinded observers retrospectively utilised digital software to template 50 consecutive patients who had hip hemiarthroplasty. The templated parameters (head size, offset and stem size) derived from pre-operative radiographs were compared to the actual prosthetic sizes used intra-operatively. Inter and intra-observer variabilities were calculated.
resultsBoth observers correctly templated the offset and head size (± 2 mm) used in 90% (n = 45) of cases. The femoral stem size (± 1 size) was correctly predicted by templating in over 84% of the cases (n = 42). Inter-observer agreement was excellent for femoral head size with an intra-class correlation coefficients (ICC) of 0.94, substantial for offset (k = 0.7) but only fair for stem size (k = 0.27). ICC values comparing the actual prostheses inserted with the template values were excellent for head size (ICC = 0.96), substantial to near perfect for offset (k = 0.78, 0.85) and fair to moderate (k = 0.24, 0.45) for stem size.
conclusionDigital templating of radiographs without calibration can be used to accurately and reliably predict femoral head size and offset at a set magnification of 120%. Femoral stem size, however, is more difficult to template adequately on pre-operative radiographs without calibration.
Indexed as
Identifiers
30209525What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.