Evidence map›Paper›PMID 30203474›Full record

ArticleMedical physics2018

Introduction of a pseudo demons force to enhance deformation range for robust reconstruction of super-resolution time-resolved 4DMRI.

Guang Li, August Sun, Xingyu Nie, Jason Moody, Kirk Huang, Shirong Zhang, Satyam Sharma, Joseph Deasy

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Guang LiDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
August SunDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Xingyu NieDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Jason MoodyDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Kirk HuangDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Shirong ZhangDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Satyam SharmaDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Joseph DeasyDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Memorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Elisa de Stanchina · 1985 to 2026
$347.4M
Training and Career Development CoreU54CA132378 · NCI · CITY COLLEGE OF NEW YORK · PI Bao Q Vuong · 2008 to 2026
$28.9M
Training and Career Development and Education CoreU54CA137788 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI ADRIANA ESPINOSA, FRANCESCA M GANY · 2008 to 2026
$28.1M
NCI NIH HHS P30 CA008748NCI NIH HHS U54 CA132378NCI NIH HHS U54 CA137788
6 · The paper itself

Abstract

purposeThe purpose of this study was to enhance the deformation range of demons-based deformable image registration (DIR) for large respiration-induced organ motion in the reconstruction of time-resolved four-dimensional magnetic resonance imaging (TR-4DMRI) for multi-breath motion simulation.

methodsA demons-based DIR algorithm was modified to enhance the deformation range for TR-4DMRI reconstruction using the super-resolution approach. A pseudo demons force was introduced to accelerate the coarse deformation in a multi-resolution (n = 3) DIR approach. The intensity gradient of a voxel was applied to its neighboring (5 × 5 × 5) voxels with a weight of Gaussian probability profile (σ = 1 voxel) to extend the demons force, especially on those voxels that have little intensity gradience but high-intensity difference. A digital 4DMRI phantom with 3-8 cm diaphragmatic motions was used for DIR comparison. Six volunteers were scanned with two high-resolution (highR: 2 × 2 × 2 mm

resultsUsing the digital phantom, the maximum deformable magnitude is doubled using the modified DIR from 3 to 6 cm at the diaphragm. In six human subjects, the first 15-iteration DIR using the pseudo force deforms 200 ± 150% more than the original force, and succeeds in all 12 cases, whereas the original demons-based DIR failed in 67% of tested cases. Using the pseudo force, high VIC (>0.9) and small ICE (1.6 ± 0.6 mm) values are observed for DIR of BHI&BHE, BHI→FB, and BHE→FB. The CCC identifies four questionable cases, in which two cases need further DIR refinement, without missing true negative.

conclusionsThe introduction of a pseudo demons force enhances the largest deformation magnitude up to 6 cm. The cross-consistency check ensures the quality of TR-4DMRI reconstruction. Further investigation is ongoing to fully characterize TR-4DMRI for potential multi-breathing-cycle radiotherapy simulation.

Indexed as

Magnetic Resonance ImagingHumansImaging, Three-DimensionalPhantoms, Imagingdeformable image registration (DIR)image-guided radiotherapy (IGRT)multi-breath motion assessmenttime-resolved four-dimensional magnetic resonance image (TR-4DMRI)

Identifiers

PMID30203474
PMCPMC6278596
OpenAlexW2890107624

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.